Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | >2 Years |
Still deciding? Get samples of US$ 7.7/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1.Full range AC 85-264V Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
Model | S-100-5 | S-100-12 | S-100-18 | S-100-24 | S-100-36 | S-100-48 |
DC output voltage,current | 5V 0~20A | 12V 0~8.5A | 18V 0~5.5A | 24V 0~4.5A | 36V 0~3A | 48V 0~2.1A |
Wave and noise | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet wire stabilily | ±0.5% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | ±0.2% |
Load stability | ±0.5% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | ±0.2% |
Efficiency | 78% | 81% | 84% | 84% | 84% | 84% |
Adjustable range for DC voltage |
±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
Input voltage range | 90~132VAC/180~264VAC by switch 254~370VDC 47~63Hz | |||||
Impact current | Cold start current 30A/115VAC 60A/230VAC | |||||
Overload protection | 105% -150% cut off the output, automatic recovery | |||||
Over voltage protection | ||||||
Setup, rise, hold up time | 200ms, 50ms, 20ms/230VAC at full load | |||||
Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV OP-FG: 0.5kV 1 minute | |||||
Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | |||||
Working temperature | -10ºC~+50ºC | |||||
Dimension | 199 x 98 x 38 mm | |||||
Weight | 0.6kg | |||||
Packing | 43 x 32.5 x 24CM/30PCS/18kg |