Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 3 Years |
Still deciding? Get samples of US$ 28.57/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | ICL-28R | ICL-28L | |||
AC INPUT VOLTAGE | 180~264VAC | 180~264VAC | |||
AC LINE FREQUENCY | 47~63Hz | ||||
INRUSH CURRENT LIMITING | 48A | ||||
AC CONTINUOUS RATED CURRENT | 28A continuous | ||||
AC INPUT POWER | 6440VA(28Ax230VAC) | ||||
AC INPUT CONSUMPTION | <2Wat264VAC,50Hz input | ||||
INTERNAL RELAY LIMITING TIME (TON POWER ON) |
150±50ms | ||||
INTERNAL RELAY | LIMITING CYCLES | 3 cycle/1 min | |||
RELEASE TIME | 100±50ms | ||||
INTERNAL PROTECTION | Thermal fuse protects overload and fire | ||||
ALLOWED CAPACITIVE LOAD | 6000μF max. | ||||
WORKING TEMP. | -30~+70ºC (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20~90%RH non-condensing | ||||
STORAGE TEMP. | -40~+85ºC | ||||
TEMP.COEFFICIENT | ±0.03%/ºC(0~60ºC)RH non-condensing | ||||
VIBRATION | 10~500Hz,2G 10min./1cycle,period for 60min.each along X,Y,Zaxes; | ||||
Mounting:Compliance to IEC60068-2-6 | |||||
OPERATING ALTITUDE Note.2 | 5000 meters | ||||
OVER VOLTAGE CATEGORY | ;According to IEC62368-1;altitude up to 5000 meters | ||||
POLLUTION DEGREE | 2 | ||||
SAFETY STANDARDS | LVD BS EN/EN62368-1 approved | ||||
SAFETY& EMC (Note.3) |
EMC EMISSION | Parameter | Standard | Test Level/Note | |
Conducted | BS EN/EN55032 | ClassB | |||
Radiated | BS EN/EN55032 | Class B | |||
HarmonicCurrent | BSEN/EN61000-3-2 |
ClassA |
|||
Voltage Flicker | BS EN/EN61000-3-3 | ------- | |||
EMC IMMUNITY | BS EN/EN55035,BS EN/EN61000-6-2 | ||||
Parameter | Standard | Test Level/Note | |||
ESD | BS EN/EN61000-4-2 | Level 3,8KVair;Level2,4KV contact,criteria A | |||
Radiated Susceptibilit | BS EN/EN61000-4-3 | Level 3,criteriaA | |||
EFT/Burest | BS EN/EN61000-4-4 | Level 3,criteriaA | |||
Surge | BS EN/EN61000-4-5 | Level 4,2KV/L-N,criteriaA | |||
Conducted | BS EN/EN61000-4-6 | Level 3,criteria A | |||
Magnetic Field | BS EN/EN61000-4-8 | Level 4,criteriaA | |||
Voltage Dips and interruptions | BS EN/EN61000-4-11 | >95%dip 0.5 periods,30%dip 25 periods, >95%interruptions 250 periods |
|||
MTBF | 6781.7K hrs min.Telcordia SR-332(Bellcore); 1601.8K hrsmin.MIL-HDBK-217F (25ºC) |
6781.7K hrs min.Telcordia SR-332(Bellcore); 1626.6K hrs min.MIL-HDBK-217F (25ºC) |
|||
DIMENSION | 52.5*90*54.5mm (L*W*H) | 175*42*24mm (L*W*H) | |||
PACKING | 0.16Kg;80pcs/13.8Kg/1.23CUFT | 0.155Kg;84pcs/14Kg/0.91CUFT | |||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft) 3.The power supply is considered as an independent unit,but the final equipment stll need to re-confim that the whole system complies with the EMC directives.For guidance on how to perform these EMC tests,please refer to"EMI testing of component power supplies. " |