Features:
1. Full Range Input Voltage
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 36 months warranty

| Model | DR-60-5 | DR-60-12 | DR-60-15 | DR-60-24 |
| DC output voltage | 5V 0~6.5A | 12V 0~4.5A | 15V 0~4A | 24V 0~2.5A |
| Wave and noise | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
| Inlet wire stabilily | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load stability | ±1% | ±0.5% | ±0.5% | ±0.5% |
| Efficiency | 76% | 82% | 83% | 84% |
| Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% |
| Input voltage range | 85~264VAC 120~370VDC 47~63Hz | |||
| Impact current | Cold start current 18A/115VAC 36A/230VAC | |||
| Overload protection | 105%~160% cut off the output, automatic recovery | |||
| Over voltage protection | 115%~135% shut down O/P voltage, re-power on to recover | |||
| Setup, rise, hold up time | 800ms, 60ms, 50ms/230VAC at full load | |||
| Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV OP-FG: 0.5kV 1 minute | |||
| Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | |||
| Working temperature | -10ºC~+50ºC | |||
| Dimension | 78 x 93 x 56mm | |||
| Weight | 0.3kg | |||
| Packing | 43 x 32 x 21.5CM/45PCS/13.5kg | |||