Features:
1. AC input range selectable by switch
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
Rated Current | 2.4A | 1.5A | 1A | 0.63A |
Current Range | 0~2.4A | 0~1.5A | 0~1A | 0~0.63A |
Rated Power | 12W | 15W | 15W | 15.2W |
Ripple & Noise | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Load Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Setup, Rise Time | 1000ms,50ms/230VAC 1000ms,50ms/115VAC at full load | |||
Hold up Time | 70ms/230VAC 16ms/115VAC at full load | |||
Voltage Range | 85~264VAC 120~370VDC | |||
Frequency Range | 47~63Hz | |||
Efficiency | 77% | 84% | 83.5% | 85% |
AC Current | 0.88A/115VAC 0.48/230VAC | |||
Inrush Current | Cold start 35A/115VAC 65A/230VAC | |||
Over Load | 105 ~ 160% rated output power | |||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||
Working Temp | -20 ~ +60ºC (Refer to "Derating Curve") | |||
Working Humidity | 20 ~ 90% RH non-condensing | |||
Storange Temp.,Humidity | -40 ~ +85ºC, 10 ~ 95% RH | |||
Temp Coefficient | ±0.03%/ºC (0 ~ 50ºC) | |||
Withstand Voltage | I/P-O/P:1.5 KVAC | |||
lsolation Resistance | I/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH | |||
Dimension | 25*93*56mm | |||
Weight | 0.1Kg |