Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1. 95-264V AC Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
Model | XLG-100-12 | XLG-100-15 | XLG-100-24 | XLG-100-27 | XLG-100-36 | XLG-100-48 |
DC output voltage | 12V | 15V | 24V | 27V | 36V | 48V |
Rated output current | 8.3A | 6.6A | 4.2A | 3.7A | 2.8A | 2.1A |
Constant current range | 6~12V | 7~15V | 12~24V | 14~27V | 18~36V | 24~48V |
Output power | 99.6W | 99W | 100.8W | 100W | 100.8W | 100.8W |
Wave and noise | 150mVp-p | 150mVp-p | 180mVp-p | 180mVp-p | 180mVp-p | 200mVp-p |
Voltage accuracy | ± 3% | ± 2% | ± 2% | ± 2% | ± 2% | ± 2% |
Line regulation | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
Load regulation | ± 2% | ± 1% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
Start, rise, hold time | 500ms,80ms,16ms/230VAC (at full load) | |||||
Input voltage range | 95 ~264VAC,135 ~373VDC | |||||
Frequency range | 47 ~ 63Hz | |||||
AC input current | 2.2A/115VAC 1.2A/230VAC | |||||
Efficiency | 87.5% | 87.5% | 89.0% | 89.0% | 90.0% | 91.0% |
Impulse current | Cold start current 55A/230VAC | |||||
Leakage current | <2mA/240VAC | |||||
Overcurrent protection | 95%~108% of the rated output current starts overcurrent limit, recover automatically after abnormal conditions are removed |
|||||
Short circuit protection | Hiccup mode: recover automatically normal output after abnormal conditions are removed | |||||
Working temperature | -20ºC~ +60ºC | |||||
Working humidity | 20% ~90% RH, non condensing | |||||
Storage temperature and humidity | -40ºC~ +85ºC;10% ~95% RH,non condensing | |||||
Seismic resistance | 10~500Hz,,3G 10min/ 1 cycle,X, Y, Z axes,duration 60 minutes | |||||
Pressure resistance | I/P~O/P: 1.5KVAC I/P~FG:1.5KVAC O/P~FG::0.5KVAC | |||||
Isolation resistance | I/P~O/P,I/P~FG,O/P~FG: 100M Ohms/500VDC/25ºC/70%RH | |||||
Safety standard | Compliance to UL60950-1,TUV EN60950-1, GB19510.1,KC61347-1,IP67 | |||||
Electromagnetic compatibility emission | Compliance to EN55022 Class A,GB17625.1,EN55015 | |||||
Electromagnetic compatibility immunity | Compliance to EN55024 | |||||
Dimension | 190*49*34mm (L*W*H) | |||||
Packing | 0.65kg/30pcs/20.5kg/0.025 cubic meters |