| Output Type: | Single |
| Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1. 220V AC Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
| Model | XLG-800-48 |
| DC output voltage | 48V |
| Rated output current | 16.5A |
| Current range | 0~16.5A |
| Output power | 792W |
| Wave and noise | 240mVp-p |
| Voltage accuracy | ± 1.5% |
| Line regulation | ± 0.5% |
| Load regulation | ± 0.5% |
| Start, rise, hold time | 500ms,50ms,24ms/230VAC (at full load) |
| Input voltage range | 180 ~264VAC,245 ~373VDC |
| Frequency range | 47 ~ 63Hz |
| AC input current | 7.5A/230VAC |
| Efficiency | 92.5% |
| Impulse current | Cold start current 65A/230VAC |
| Leakage current | <2mA/240VAC |
| Overcurrent protection | 95%~108% of the rated output current starts overcurrent limit, recover automatically after abnormal conditions are removed |
| Short circuit protection | Protection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed |
| Overvoltage protection | 115%~ 135% of rated output voltage startup overvoltage protection |
| Protection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed | |
| Over temperature protection | 105ºC ±5ºC (JK1/JK2 is next to the transformer/MOS tube surface detection) |
| Protection mode: Turn Off the output voltage, and the normal output can be automatically restored after the temperature drops |
|
| Working temperature | -20ºC~ +60ºC |
| Working humidity | 20% ~90% RH, non condensing |
| Storage temperature and humidity | -40ºC~ +85ºC;10% ~95% RH,non condensing |
| Seismic resistance | 10~500Hz,,5G 12min/ 1 cycle,X, Y, Z axes,duration 72 minutes |
| Pressure resistance | I/P~O/P:1.5KVAC I/P~FG:1.5KVAC O/P~FG:0.5KVAC |
| Isolation resistance | I/P~O/P,I/P~FG,O/P~FG: 100M Ohms/500VDC/25ºC/70%RH |
| Safety standard | Compliance to UL60950-1,TUV EN60950-1 |
| Electromagnetic compatibility emission | Compliance to EN55022 Class A |
| Electromagnetic compatibility immunity | Compliance to EN55024 |
| Dimension | 265*120*56mm (L*W*H) |
| Packing | 2.75kg/6pcs/17.5kg/0.033 cubic meters |