Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 72/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1. 220V AC Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
Model | XLG-1200-48 |
DC output voltage | 48V |
Rated output current | 25A |
Current range | 0~25A |
Output power | 1200W |
Wave and noise | 240mVp-p |
Voltage accuracy | ± 2% |
Line regulation | ± 0.5% |
Load regulation | ± 0.5% |
Start, rise, hold time | 500ms,50ms,24ms/230VAC (at full load) |
Input voltage range | 180 ~264VAC,245 ~373VDC |
Frequency range | 47 ~ 63Hz |
AC input current | 11A/230VAC |
Efficiency | 94.0% |
Impulse current | Cold start current 65A/230VAC |
Leakage current | <2mA/240VAC |
Overcurrent protection | 95%~108% of the rated output current starts overcurrent limit, recover automatically after abnormal conditions are removed |
Short circuit protection | Protection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed |
Overvoltage protection | 115%~ 135% of rated output voltage startup overvoltage protection |
Protection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed | |
Over temperature protection | 105ºC ±5ºC (JK1/JK2 is next to the transformer/MOS tube surface detection) |
Protection mode: Turn Off the output voltage, and the normal output can be automatically restored after the temperature drops |
|
Working temperature | -20ºC~ +60ºC |
Working humidity | 20% ~90% RH, non condensing |
Storage temperature and humidity | -40ºC~ +85ºC;10% ~95% RH,non condensing |
Seismic resistance | 10~500Hz,,5G 12min/ 1 cycle,X, Y, Z axes,duration 72 minutes |
Pressure resistance | I/P~O/P:1.5KVAC I/P~FG:1.5KVAC O/P~FG:0.5KVAC |
Isolation resistance | I/P~O/P,I/P~FG,O/P~FG: 100M Ohms/500VDC/25ºC/70%RH |
Safety standard | Compliance to UL60950-1,TUV EN60950-1 |
Electromagnetic compatibility emission | Compliance to EN55022 Class A |
Electromagnetic compatibility immunity | Compliance to EN55024 |
Dimension | 340*120*56mm |
Weight | 3.45kg |