MODEL | RSP-1500-5 | RSP-1500-12 | RSP-1500-15 | RSP-1500-24 | RSP-1500-27 | RSP-1500-48 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 27V | 48V |
RATED CURRENT | 240A | 125A | 100A | 63A | 56A | 32A | |
CURRENT RANGE | 0~240A | 0~125A | 0~100A | 0~63A | 0~56A | 0~32A | |
RATED POWER | 1200W | 1500W | 1500W | 1512W | 1512W | 1536W | |
RIPPLE &NOISE(max.)Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ.RANGE | 4.5~5.5V | 10~13.5V | 13.5~16.5V | 20~26.4V | 24~30V | 43~56V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP,RISE TIME | 1500ms,100ms at full load | ||||||
HOLD UPTIME(Typ.) | 10msat full load | 14ms at full load | 16ms at full load | ||||
INPUT | VOLTAGE RANGE | 90~264VAC 127~370VDC | |||||
FREQUENCY RANGE | 47~63Hz | ||||||
POWER FACTOR(Typ.) | 0.95/230VAC 0.98/115VAC at full load | ||||||
EFFICIENCY(Typ.) | 80% | 87% | 87% | 90% | 90% | 91% | |
AC CURRENT(Typ.) | 17A/115VAC 8A/230VAC | ||||||
INRUSH CURRENT(Typ.) | 30A/115VAC 60A/230VAC | ||||||
LEAKAGE CURRENT | <2.0mA/240VAC | ||||||
PROTECTION | OVERLOAD Note.4 | 105~135%rated output power | |||||
Protection type:Constant current limiting unit will shut down o/p voltage after 5sec.Re-power on to recover | |||||||
OVER VOLTAGE | 5.75~6.75V | 13.8~16.8V | 17~20.5V | 27.6~32.4V | 31~36.5V | 57.6~67.2V | |
Protection type:Shut down o/p voltage,re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage,recovers automatically after temperaturegoes down | ||||||
FUNCTION | 0UTPUT VOLTAGE PROGRAMMABLE(PV) | Adjustment of output voltageis allowable to 70~100%of nominal output voltage.Please refer to the Function Manual. | |||||
CURRENT SHARING | Up to 6000Wor (3+1)units.Please refertothe Function Manual. | ||||||
AUXILIARY POWER | [email protected](Only for Remote ON-OFF control) | ||||||
REMOTE ON-OFF CONTROL | Please see the Function Manual. | ||||||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.3V.Please refer to the Function Manual. | ||||||
ALARM SIGNALOUTPUT | Power OK signal.Please see the Function Manual. | ||||||
ENVIRONMENT | WORKING TEMP. | -20~+70ºC (Refer to "Derating Curve" | |||||
WORKING HUMIDITY | 20~90%RH non-condensing | ||||||
STORAGETEMP.,HUMIDITY | -40~+85ºC,10~95%RH non-condensing | ||||||
TEMP.COEFFICIENT | ±0.05%/ºC (0~50ºC) | ||||||
VIBRATION | 10~500Hz,2G 10min./1cycle,60min.each alongX,Y,Z axes | ||||||
SAFETY& EMC (Note 5) |
SAFETY STANDARDS | UL62368-1,CAN/CSAC22.2No.62368-1,TUVBSEN/EN62368-1,BSMICNS15598-1,ASINZS62368.1,EAC TPTC004 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25ºC/70%RH | ||||||
EMC EMISSION | Parameter | Standard | Test Level /Note | ||||
Conducted | BS EN/EN55032(CISPR32),BSMICNS15936 | Class B/Class A(only for BSMI) | |||||
Radiated | BSEN/EN55032(CISPR32),BSMI CNS15936 | Class A | |||||
Harmonic Current | BS EN/EN61000-3-2 | ||||||
Voltage Flicker | BS EN/EN61000-3-3 | ||||||
EMC IMMUNITY | BS EN/EN55035,BS EN/EN61000-6-2 | ||||||
Parameter | Standard | Test Level/Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3,8KVair;Level2,4KV contact | |||||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||||
EFT/Burst | BS EN/EN61000-4-4 | Level2 | |||||
Surge | BS EN/EN61000-4-5 | Level 3,2KV/Line-Earth;Level2,1KV/Line-Line | |||||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95%dip 0.5 periods,30%dip 25 periods, >95%interruptions 250 periods |
|||||
OTHERS | MTBF | 814.4Khrs min.Telcordia SR-332(Bellcore);90.4Khrs min.MIL-HDBK-217F(25ºC) | |||||
DIMENSION | 278*127*83.5mm(L*W*H) | ||||||
PACKING | 3.0Kg;4pcs/13Kg/1.19CUFT | ||||||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire teminated with a 0.1uf &47uf paralel capacitor. 3.Tolerance :includes set up tolerance,line regulation and load regulation. 4.Derating may be needed under low input voltages.Please check the derating curve for more details 5.The power supl is considered a component which il einstaled into a inal equipment Althe EMC tests are beenexecuted by mountng the unit on a720mm*360mm meta plate with 1mm of hickness.Thefinal equipment mustbe re-confirmed that itstll meets EMC drectves.For guidance on how to perform these EMC tests,please refer to "EMI testing of component power supplies. (as available on Upload/PDF/EMI_statement_en.pdf) 6.The ambient temperature deratng of 3.5ºC1000m with fanless modes and of 5ºC1000m with fan modes for perating alftude higher han 2000m(6500t) |