Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 5 Years |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | UHP-200-3.3 | UHP-200-4.2 | UHP-200-5 | UHP-200-12 | UHP-200-15 | UHP-200-24 | UHP-200-36 | UHP-200-48 | UHP-200-55 | |
OUTPUT | DC VOLTAGE | 3.3V | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V | 55V |
RATED CURRENT | 40A | 40A | 40A | 16.7A | 13.4A | 8.4A | 5.6A | 4.2A | 3.6A | |
RATED POWER | 132W | 168W | 200W | 200.4W | 201W | 201.6W | 201.6W | 201.6W | 201.6W | |
RIPPLE &NOISE(max.)Note.2 | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 300mVp-p | 360mVp-p | |
VOLTAGEADJ.RANGE | 3.2~3.5V | 3.6~4.4V | 4.5~5.5V | 11.4~12.6V | 14.3~15.8V | 22.8~25.2V | 34.2~37.8V | 45.6~50.4V | 45~58V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | +2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP,RISE TIME | 2000ms,80ms/230VAC;3000ms,80ms/115VAC atful load;550ms/230VAC for 55V setup time | |||||||||
HOLD UP TIME(Typ.) | 10ms/230VAC 10ms/115VAC |
|||||||||
INPUT | VOLTAGE RANGE Note.4 |
90~264VAC 127~370VDC | ||||||||
FREQUENCYRANGE | 47~63Hz | |||||||||
POWER FACTOR(Typ.) | PF≥0.94/230VAC PF≥0.98/115VAC at full load | |||||||||
EFFICIENCY(Typ.) | 89% | 90% | 91% | 93% | 94% | 94% | 94% | 94% | 94% | |
AC CURRENT (Typ.) | 2.2A/115VAC 1.1A/230VAC | |||||||||
INRUSH CURRENT (Typ.)Note.8 | Coldstart 40A/115VAC 80A/230VAC | |||||||||
LEAKAGECURRENT | <0.75mA/240VAC | |||||||||
PROTECTION | OVERLOAD | 110~140%rated output power | ||||||||
Protection type:Hiccup mode,recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | 3.8~4.6V | 4.62~5.46V | 5.75~6.75V | 13.2~15.6V | 16.5~19.5V | 26.4~31.2V | 39.6~46.8V | 52.8~62.4V | 60~69V | |
Protection type :Shut down O/P voltage,re-power on to recover | ||||||||||
OVER TEMPERATURE | Protection type:Shut down O/P voltage orHiccup mode,recovers automaticallyafter temperature goes down | |||||||||
FUNCTION | DC OK SIGNAL(Optional) | Contactrating(max.):15Vdc/10mA resistive load | ||||||||
REDUNDANT(Optional) | For parallel connection protection:For parallel applications,when one PSU can not work,the another one will be automatically enabled.This can prevent the system crash,and provide the reliability of system |
|||||||||
ENVIRONMENT | WORKING TEMP. | -30~+70ºC(Refer to "Derating Curve") | ||||||||
WORKING HUMIDITY | 20~95%RH non-condensing | |||||||||
STORAGE TEMP.,HUMIDITY | -40~+85ºC,10~95%RH non-condensing | |||||||||
TEMP.COEFFICIENT | ±0.03%/ºC (0~50ºC) | |||||||||
VIBRATION | 10~500Hz,5G 10min.1cycle,60min.each along X,Y,Z axes | |||||||||
SAFETY& EMC (Note.6) |
SAFETY STANDARDS | UL62368-1,TUVBS EN/EN62368-1,BS EN/EN60335-1(Except for 55V),GB4943.1,EAC TP TC 004 KC62368-1(only for UHP-200-24),BS EN/EN61558-1,BS EN/EN61558-2-16,BSMI CNS15598-1 approved |
||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,0/P-FG:100M Ohms/500VDC/25ºC/70%RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032,GB17625.1,GB/T 9254.1,Class B,BS EN/EN55014,BS EN/EN61000-3-2,-3, EAC TP TC020,BSMI CNS15936 |
|||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2(BS EN/EN50082-2),BS EN/EN55035, heavy industry level ,EAC TP TC 020 |
|||||||||
OTHERS | MTBF | 2472.1Khrs min.Telcordia SR-332(Bellcore);257.0Khrs min.MIL-HDBK-217F(25ºC) | ||||||||
DIMENSION | 194*55*26mm(L*W*H) | |||||||||
PACKING | 0.468kg;24pcs/12.2kg/0.49CUFT | |||||||||
NOTE |
1.All parameters NOTspecially mentioned aremeasured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wireterminated with a 0.1uf &47uf parallel capacitor. 3.Tolerance :includes set up tolerance,line regulation and load regulation. 4.Derating may be needed under low input voltages.Please check thederating curve for more details. 5.The ambient temperature derating of 5ºC/1000m is needed for operating altitude greater than 2000m(6500ft) 6.The powersupply is considered a component which willbeinstalled into afinal equipment.The final equipment must bere-confirmed that it sill meets EMC directives.For guidance on how to perform these EMC tests,please referto"EMI testing of component power supplies. " 7.R type efficiency slightly less than the Blank type,according to the actual measurement. 8.Inrush current parameter has 10%tolerance. 9.RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. |