Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 15.42/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1.Full range AC 85-264V Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
Model | SC-180-12 | SC-180-24 | ||
DC voltage | CH1:12V | CH2:13.8V | CH1:24V | CH2:27.6V |
Output voltage tolerance | ±2% | ----- | ±2% | ----- |
Rated current | 13.5A | 1.5A | 6.5A | 1.0A |
Current range | 0~15A | ----- | 0~7.5A | ----- |
Rated power | 182.7W | 183.6W | ||
Ripple and noise | 120mvp-p | ----- | 180mvp-p | ----- |
Voltage adjustable range | CH1:10.3~13.8V | CH1:21.3~27.5V | ||
Efficiency | 85% | 87% | ||
Input voltage range | 90~132VAC/180~264VAC(selected by switch) or 255~370VDC | |||
Frequency | 47~63HZ | |||
AC input current | 3.5A/115VAC,1.8A/230VAC | |||
Impulse current | Cold-start current 30A/115VAC,50A/230VAC | |||
Leakage current | < 2.5mA/240VAC | |||
Overload load protection | Rated output power 110%~150% start overload load protection | |||
Protection type:AC charging mode,hiccup mode,auto-revovery after condition is removed | ||||
Battery low-voltage protection | 9.5~10.3V | 19~20.6V | ||
Protection type : cut off the output | ||||
UPS Introduction | Long-term online floating charge to the battery, high charging efficiency, the battery can saturate to more than 90%; | |||
Auto-stop charging when it's full, percent overcharging. Effectively extend battery life; | ||||
AC/battery auto switch, no switching time, no need for human guard; | ||||
Cold-start, when there is no AC input, can use battery start UPS, Meet the user's emergency needs. | ||||
Working temperature and humidity | -20ºC~+60ºC,20%~90%RH | |||
Storage temperature and humidity | -20ºC~+85ºC,10%~95%RH Non-condensing | |||
Withstand voltage | I/P-O/P:1.5KVAC; I/P-F/G:1.5KVAC; O/P-F/G:0.5KVAC | |||
Isolation resistance | I/P-O/P,I/P-F/G,O/P-F/G:100M ohms/500VDC | |||
Demension | 199*98*38mm (L*W*H) | |||
Weight/Packing | 0.6kg/30pcs/18kg |