MODEL | TDR-240-24 | TDR-240-48 | |||||||||||||||||||||||||||||||
OUTPUT | DC VOLTAGE | 24V | 48V | ||||||||||||||||||||||||||||||
RATED CURRENT | 10A | 5A | |||||||||||||||||||||||||||||||
CURRENT RANGE | 0 ~ 10A | 0 ~ 5A | |||||||||||||||||||||||||||||||
RATED POWER | 240W | 240W | |||||||||||||||||||||||||||||||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | |||||||||||||||||||||||||||||||
VOLTAGE ADJ. RANGE | 24 ~ 28V | 48 ~ 55V | |||||||||||||||||||||||||||||||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | |||||||||||||||||||||||||||||||
LINE REGULATION | ±0.5% | ±0.5% | |||||||||||||||||||||||||||||||
LOAD REGULATION | ±1.0% | ±1.0% | |||||||||||||||||||||||||||||||
SETUP, RISE TIME | 2000ms, 60ms/400VAC 1500ms, 60ms/500VAC at full load | ||||||||||||||||||||||||||||||||
HOLD UP TIME (Typ.) | 20ms / 400VAC 40ms / 500VAC at full load | ||||||||||||||||||||||||||||||||
INPUT | VOLTAGE RANGE Note.4 | Three-Phase 340 ~ 550VAC (Dual phase operation possible in connecting L1,L3,FG orL2,L3,FG) or 480 ~ 780VDC | |||||||||||||||||||||||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||||||||||||||||||||||
POWER FACTOR (Typ.) | PF>=0.53/400VAC PF>=0.52/500VAC at full load | ||||||||||||||||||||||||||||||||
EFFICIENCY (Typ.) | 92% | 92% | |||||||||||||||||||||||||||||||
AC CURRENT (Typ.) | 0.69A/400VAC 0.6A/500VAC | ||||||||||||||||||||||||||||||||
INRUSH CURRENT (Typ.) | COLD START 50A | ||||||||||||||||||||||||||||||||
LEAKAGE CURRENT | <2mA / 530VAC | ||||||||||||||||||||||||||||||||
PROTECTION | OVERLOAD | 105 ~ 130% rated output power | |||||||||||||||||||||||||||||||
Protection type : Constant current limiting, unit will hiccup after 3 sec. | |||||||||||||||||||||||||||||||||
OVER VOLTAGE | 30 ~ 36V | 56 ~ 65V | |||||||||||||||||||||||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed. | |||||||||||||||||||||||||||||||||
OVER TEMPERATURE | Shutdown o/p voltage, recovers automatically after temperature goes down | ||||||||||||||||||||||||||||||||
FUNCTION | DC OK REALY CONTACT RATINGS (max.) | 60VDC/0.3A, 30VDC/1A, 30VAC/0.5Aresistive load | |||||||||||||||||||||||||||||||
ENVIRONMENT | WORKING TEMP. Note.5 | -30 ~ +70ºC (Refer to "Derating Curve") | |||||||||||||||||||||||||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||||||||||||||||||||||||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85ºC , 10 ~ 95% RH non-condensing | ||||||||||||||||||||||||||||||||
TEMP. COEFFICIENT | ±0.05%/ºC (0 ~ 60ºC) | ||||||||||||||||||||||||||||||||
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||||||||||||||||||||||||||||||||
OPERATING ALTITUDE Note.6 | 5000 meters | ||||||||||||||||||||||||||||||||
OVER VOLTAGE CATEGORY | According to EN61558, EN50178, EN60664-1, EN62477-1, EN60204-1; altitude up to 2000 meters | ||||||||||||||||||||||||||||||||
SAFETY & EMC (Note 7) |
SAFETY STANDARDS | UL61010-1, UL61010-2-201, BS EN/EN61558-1, BS EN/EN61558-2-16, BIS IS13252(Part1)(only for 24V), EACTPTC 004 approved, design refer to AS/NZS61558-1/-2-16 |
|||||||||||||||||||||||||||||||
WITHSTAND VOLTAGE | I/P-O/P:4.87KVAC I/P-FG:2.4KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC | ||||||||||||||||||||||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25ºC/ 70% RH | ||||||||||||||||||||||||||||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | ||||||||||||||||||||||||||||||
Conducted | BS EN/EN55032(CISPR32)/BS EN/EN61204-3 | Class B | |||||||||||||||||||||||||||||||
Radiated | BS EN/EN55032(CISPR32)/BS EN/EN61204-3 | Class B | |||||||||||||||||||||||||||||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | |||||||||||||||||||||||||||||||
Voltage Flicker | BS EN/EN61000-3-3 | ----- | |||||||||||||||||||||||||||||||
EMC IMMUNITY | BS EN/EN55035 , BS EN/EN61204-3 | ||||||||||||||||||||||||||||||||
Parameter | Standard | Test Level / Note | |||||||||||||||||||||||||||||||
ESD | BS EN/EN61000-4-2 | Level 4, 15KV air ; Level 4, 8KV contact | |||||||||||||||||||||||||||||||
Radiated Field | BS EN/EN61000-4-3 | Level 3 | |||||||||||||||||||||||||||||||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | |||||||||||||||||||||||||||||||
Surge | BS EN/EN61000-4-5 | Level 4, 2KV / Line-Line, Level 4, 4KV/ Line-Earth | |||||||||||||||||||||||||||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||||||||||||||||||||||||||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||||||||||||||||||||||||||||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods> 95% interruptions 250 periods |
|||||||||||||||||||||||||||||||
OTHERS | MTBF | 1534.9K hrs min. Telcordia SR-332(Bellcore); 215.6K hrs min. MIL-HDBK-217F (25ºC) | |||||||||||||||||||||||||||||||
DIMENSION | 63*125.2*113.5mm (W*H*D) | ||||||||||||||||||||||||||||||||
PACKING | 1Kg ; 12pcs/13Kg/1.22CUFT | ||||||||||||||||||||||||||||||||
NOTE | 1. AII parameters NOT speciaIIY mentioned are measured at 400VAC input, rated Ioad and 25ºC of ambient temperature. 2. RippIe & noise are measured at 20MHz of bandwidth bY using a 12" twisted pair-wire terminated with a 0.1 μ F & 47 μ F paraIIeI capacitor. 3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation. 4. DuaI phase operation is aIIowed under certain derating to output Ioad. PIease refer to derating curves for detaiIs. 5. InstaIIation cIearances : 40mm on top, 20mm on the bottom, 5mm on the Ieft and right side are recommended when Ioaded permanentIY with fuII power. In case the adjacent device is a heat source, 15mm cIearance is recommended. 6. The ambient temperature derating of 3.5ºC/1000m is needed for operating aItitude higher than 2000m(6500ft). 7. The power suppIY is considered a component which wiII be instaIIed into a finaI equipment. The finaI equipment must be re-confirmed that it stiII meets EMC directives. For guidance on how to perform these EMC tests, pIease refer to "EMI testing of component power suppIies." |
Q1:Why choose us?
A1:Original MEANWELL brand 100% original real MEANWELL brand, and have UL, CUL, CE, CB, RoHS and other certificates. The product surface has different S/N codes, you can check the code with MEANWELL company.
Q2: Do you have any MOQ limit?
A2: No MOQ, for most models we have stock 1pcs also ok. If the model not commonly used, we will quote the price and MOQ.
Q3:What about the lead time?
A3:Delivery time about 3-7 days, mass production time depends on order quantity and model.
Q4:How do you ship the goods and how long does it takes?
A4:We usually ship via DHL, UPS, FedEx or TNT. It will takes about 3-7 days to arrive. Airline and sea shipping also optional.
Q5:Do you offer guarantee for the products?
A5:Off course, 2-7 years warranty.