Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 5 Years |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | UHP-200A-4.2 | UHP-200A-4.5 | UHP-200A-5 | |
0UTPUT | DC VOLTAGE | 4.2V | 4.5V | 5V |
RATED CURRENT | 40A | 40A | 40A | |
CURRENT RANGE | 0~40A | 0~40A | 0~40A | |
RATED POWER | 168W | 180W | 200W | |
RIPPLE&NOISE(max,)Note. | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ.RANGE | 4.0~4.4V | 4.3~4.7V | 4.7~5.3V | |
VOLTAGE TOLERANCE Note.3 | ±4.0% | ±4.0% | ±4.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.5% | ±2.5% | ±2.5% | |
SETUP.RISE TIME | 2000ms,200ms/230VAC at full load,3000ms,200ms/115VAC at 80%load | |||
HOLD UP TIME (Typ. | 10ms/230VAC 10ms/115VAC | |||
DC OK FUNCTION | PSU Turns on:DC ok;PSU turns off:DC fail | |||
INPUT | VOLTAGE RANGE Note.4 | 90~264VAC 127~370VDC | ||
FREQUENCY RANGE | 47~63Hz | |||
POWER FACTOR(Typ.) | PF≥0.97/115VAC PF≥0.95/230VAC at full load | |||
EEFICIENCY (Typ. | 88% | 88% | 88.5% | |
AC CURRENT(Typ.) | 2.4A/115VAC 1.2A/230VAC | |||
INRUSH CURRENT (Typ.) | Cold start 85A/230VAC | |||
LEAKAGE CURRENT | <1.0mA/240VAC | |||
PROTECTION | OVERLOAD | 110~140%rated output power | ||
Protection type:Hiccup mode,recovers automatically after fault condition is removed | ||||
SHORT CIRCUIT | Protection type:Hiccup mode,recovers automatically after fault condition is removed | |||
OVER VOLTAGE | 4.6~6V | 5~6.4V | 5.6~7.1V | |
Protection type:Hiccup mode,recovers automatically after fault condition is removed | ||||
OVER TEMPERATURE | Protection type:Shut down O/P voltage,recovers automatically after fault condition is removed | |||
ENVIRONMFNT | WORKING TEMP. | -30~+70ºC(Refer to"OUTPUTLOAD vs TEMPERATURE") | ||
WORKING HUMIDITY | 20~95%RH non-condensing | |||
STORAGE TEMP.,HUMIDITY | -40~+85ºC,10~95%RH | |||
TEMP.COEFFICIENT | ±0.03%/ºC (0~50ºC) | |||
VIBRATION | 10~500Hz,5G 10min./1cycle,60min.each along X,Y,Z axes | |||
SAFETY& EMC (Note.5) |
SAFETY STANDARDS | UL62368-1,TUVBS EN/EN62368-1,GB 4943.1,EAC TPTC 004 approved | ||
WITHSTAND VOLTAGE | I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25ºC/70%RH | |||
EMC EMISSION Note.8 | Compliance to BS EN/EN55032(CISPR32),GB17625.1,GB/T 9254.1,BS EN/EN61000-3-2,-3,EAC TP TC020 | |||
EMCIMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN55035,light industry level (surge 4KV),EACTP TC 020 | |||
OTHERS | MTBF | 1949.0 Khrs min.Telcordia SR-332(Bellcore);211.7K hrs min.MIL-HDBK-217F(25ºC) | ||
DIMENSION | 167*55*26mm (L*W*H) | |||
PACKING | 0.42kg;20pcs/11.4kg/0.76CUFT | |||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated witha 0.1uf &47uf paralle capacitor 3.Tolerance :line regulation and load regulation. 4.Derating may be needed under low input voltages.Pleasecheck the static characteristics for more details. 5.Length of set up time is measuredatcold frst start.Tuming ONOFF the power supply may lead to increase of the set up time 6.Transient response meansure shall be made with 10%load at least. 7.The power supply is considered a component wich wil be instaled into a finalequipment.Allthe EMC tests are been executed by mountng the unit on a360mm*360mm metal plate with 1mm of hickness.The fnal equipment must be re-confimed that it sil meets EMC drecives.For guidance on how to perform these EMC tests,please refer to "EMI testing of component power supplies." 8.Warning:This equipmentis compliant with Class A of CISPR 32.In a residential environment may cause radio interference |