MODEL | PHP-3500-24 | PHP-3500-48 | ||||||||||||||||||||
OUTPUT | DC VOLTAGE | 24V | 48V | |||||||||||||||||||
RATED CURRENT | 145A | 73A | ||||||||||||||||||||
RATED POWER | 3480W | 3504W | ||||||||||||||||||||
RIPPLE & NOISE (max.) Note.2 | 300mVp-p | 480mVp-p | ||||||||||||||||||||
VOLTAGE ADJ. RANGE | By built-in potentiometer, SVR | |||||||||||||||||||||
24~28.8V | 48~57.6V | |||||||||||||||||||||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ||||||||||||||||||||
LINE REGULATION | ±0.5% | ±0.5% | ||||||||||||||||||||
LOAD REGULATION | ±0.5% | ±0.5% | ||||||||||||||||||||
SETUP, RISE TIME Note.4 | 1500ms, 60ms/230VAC 1500ms, 60ms/115VAC at full load | |||||||||||||||||||||
HOLD UP TIME (Typ.) Note.4 | 16ms/230VAC at 75% load 10ms/230VAC at full load ; 16ms/115VAC at 75% load 10ms/115VAC at full load | |||||||||||||||||||||
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC | ||||||||||||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||||||||||||||
POWER FACTOR (Typ.) Note.4 | PF≥0.95/230VAC PF≥0.99/115VAC at full load | |||||||||||||||||||||
EFFICIENCY (Typ.) Note.10 | 95% | 96% | ||||||||||||||||||||
AC CURRENT (Typ.) | 20A/115VAC 20A/230VAC | |||||||||||||||||||||
INRUSH CURRENT (Typ.) | Cold start 30A/115VAC 80A/230VAC | |||||||||||||||||||||
LEAKAGE CURRENT | 2mA / 240VAC | |||||||||||||||||||||
PROTECTION | OVERLOAD | 105 ~ 115% rated current | ||||||||||||||||||||
Protection type : Constant current limiting, shutdown O/Pvoltage after 5 sec. After O/P voltage falls, re-power on to recover | ||||||||||||||||||||||
OVER VOLTAGE | 30 ~ 36V | 60 ~ 72V | ||||||||||||||||||||
Protection type :Shut down O/P voltage,re-power on to recover | ||||||||||||||||||||||
OVER TEMPERATURE | Protection type :Shut down O/P voltage, recovers automatically after temperature goes down | |||||||||||||||||||||
FUNCTION | OUTPUT VOLTAGE PROGRAMMABLE(PV)Note.5,6 |
Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage. Please refer to the Function Manual. | ||||||||||||||||||||
OUTPUT CURRENT PROGRAMMABLE(PC) Note.6 |
Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual. | |||||||||||||||||||||
REMOTE ON/OFF CONTROL | Power ON : Short circuit Power OFF : Open circuit | |||||||||||||||||||||
AUXILIARY POWER | [email protected] tolerance±10%, ripple 150mVp-p | |||||||||||||||||||||
DC-OK SIGNAL | The TTL signal out, PSU turn on = -0.5 ~ 0.5V ; PSU turnoff = 3.5 ~ 5.5V. Please refer to the Function Manual. | |||||||||||||||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70ºCBaseplate temperature (Refer to "Derating Curve") | ||||||||||||||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||||||||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85ºC , 10 ~ 95% RH non-condensing | |||||||||||||||||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |||||||||||||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes | |||||||||||||||||||||
OVER VOLTAGE CATEGORY | According to EN61558; altitude up to 5000 meters. | |||||||||||||||||||||
SAFETY & EMC (Note.8) |
SAFETY STANDARDS | UL62368-1, CAN/CSAC22.2 No. 62368-1,TUV BS EN/EN62368-1, EACTPTC 004 approved ; design refers to BS EN/EN61558-1, BS EN/EN60335-1 | ||||||||||||||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||||||||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25ºC/ 70%RH | |||||||||||||||||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | |||||||||||||||||||
Conducted | BS EN/EN55032 (CISPR32) | Class A | ||||||||||||||||||||
Radiated | BS EN/EN55032 (CISPR32) | Class A | ||||||||||||||||||||
Harmonic Current | BS EN/EN61000-3-12 | ----- | ||||||||||||||||||||
Voltage Flicker | BS EN/EN61000-3-3 | ----- | ||||||||||||||||||||
EMC IMMUNITY | BS EN/EN55035 | |||||||||||||||||||||
Parameter | Standard | Test Level / Note | ||||||||||||||||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||||||||||||||||||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||||||||||||||||||||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | ||||||||||||||||||||
Surge | BS EN/EN61000-6-2 | 2KV/Line-Line 4KV/Line-Earth | ||||||||||||||||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||||||||||||||||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||||||||||||||||||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods |
||||||||||||||||||||
OTHERS | MTBF | 544.8K hrs min. Telcordia SR-332 (Bellcore) ; 56.3K hrs min. MIL-HDBK-217F (25ºC) | ||||||||||||||||||||
DIMENSION | 380*141.4*60mm (L*W*H) | |||||||||||||||||||||
PACKING | 4.5Kg;4pcs/19Kg/2.46CUFT | |||||||||||||||||||||
NOTEf | 1. AII parameters NOT speciaIIy mentioned are measured at 230vAC input, rated Ioad and 25ºC of ambient temperature. 2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor. 3. ToIerance :includes set up tolerance, Iine reguIation and Ioad reguIation. 4. Derating may be needed under Iow input voItages. PIease check the derating curve and static characteristics for more detaiIs. 5. without water or fan cooIing to provide adequate heat dissipation, OTP might be triggered if trimming output voItage by Pv signaI toward upper or bottom Iimits of nominaI voItage. under such condition, enhanced cooIing on Psu is highIy recommended. 6. Pv/PC function when users are not operating on PMBus. svR functions when users are neither operation on PMBus nor using Pv/PC. 7. Output wiII shut down after O/P voItage is beIow < 80% of vset for 5 sec, re-power on to recover. 8. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by mounting the unit on a 600mm*900mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directives. For guidance on how toperform these EMC tests, pIease refer to "EMI testing of component power suppIies." 9. The ambient temperature derating of 3.5ºC/1000m with fanIess modeIs and of 5ºC/1000m with fan modeIs for operating aItitude higher than 2000m(6500ft). 10. The efficiency is measured at 75% Ioad. |
Q1:Why choose us?
A1:Original MEANWELL brand 100% original real MEANWELL brand, and have UL, CUL, CE, CB, RoHS and other certificates. The product surface has different S/N codes, you can check the code with MEANWELL company.
Q2: Do you have any MOQ limit?
A2: No MOQ, for most models we have stock 1pcs also ok. If the model not commonly used, we will quote the price and MOQ.
Q3:What about the lead time?
A3:Delivery time about 3-7 days, mass production time depends on order quantity and model.
Q4:How do you ship the goods and how long does it takes?
A4:We usually ship via DHL, UPS, FedEx or TNT. It will takes about 3-7 days to arrive. Airline and sea shipping also optional.
Q5:Do you offer guarantee for the products?
A5:Off course, 2-7 years warranty.