PSC-500-12 Battery Charger UPS AC to DC Smps Industrial Switching Power Supply 13.8V 25A and 10A by Charger Power Supply
Features:
1. International universal AC input voltage range
2.Small size, light weight, high efficiency
3.Protection features: short circuit/overload
4.Battery low voltage protection
5.With power on/charging/mains power display (LED)
6.100% full load burn-in test
7.Power on LED indicator
8.3-year quality assurance
| Model | PSC-500-12 | PSC-500-24 | ||
| DCOutputVoltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2:27.6V |
| OutputVoltageTolerance | ±1.5% | ----- | ±1.5% | ----- |
| RatedOutputCurrent | 25A | 10A(charge) | 13.5A | 5A(charge) |
| OutputCurrentRange | 0~35A | ----- | 0~18.5A | ----- |
| OutputPower | 500W | 500W | ||
| RippleandNoise | 240mVp-p | ----- | 300mVp-p | ----- |
| AdjustableRangeofDCVoltage | CH1:11.3~14.9V | CH1:21.3~29.8V | ||
| Start-up,Rise,andHoldTime | 600ms,50ms,80ms/230VAC.1200ms.50ms.16ms/115VAC. | |||
| InputVoltageRange | 90~132VAC/180~264VAC By Switch 235~370VDC | |||
| AClnputCurrent | 9.5A/115VAC 5.5A/230VAC | |||
| Efficiency | 87% | 89% | ||
| InrushCurrent | Cold Start Current 45A/115VAC 55A/230VAC | |||
| LeakageCurrent | <1mA/240VAC | |||
| OverloadProtection | Overload protection will be activated at105%to 115%of the rated output power. | |||
| Protection mode:AC charging mode:hicups mode,the system can automaticallyresume operation after the abnormal load condition is removed. | ||||
| LowBatteryVoltageProtection | 9.5~10.3V | 19~20.5V | ||
| Protection mode:Output cut-off. | ||||
| IntroductiontoUPSFunction | Long-term online float charging for batteries with high efficiency,over 97%fullness. | |||
| Automatically stops charging when full to prevent overcharge and extend battery life. | ||||
| Automatic switch between utility power and battery without delay,no manual operation needed. | ||||
| Cold start capability allows UPSto start directly from battery in case of no utility power,meeting emergency needs. | ||||
| OperatingTemperatureandHumidity | -30ºC to~60ºC;20%~90%RH(Please refer to the load derating curve) | |||
| StorageTemperatureandHumidity | -40ºC~+85ºC;10%~95%RH Non-condensing | |||
| ShockResistance | 10~500Hz,2G10min./percycle,duration 60 minutes,on each axis. | |||
| VoltageWithstandingCapability | Between input and output:1.5KVAC Between input and ground:1.5k VAC Between output and ground:0.5k VDC. | |||
| InsulationResistanc | Between input and output,input and ground,output and ground:100MΩ/500VDC | |||
| Dimensions | 215*115*50mm(L*W*H) | |||
| Packaging | 0.87kg/20pcs/19.5kg/0.041m³ | |||