MODEL | UHP-750-12 | UHP-750-24 | UHP-750-36 | UHP-750-48 | |||
OUTPUT | DC VOLTAGE | 12V | 24V | 36V | 48V | ||
RATED CURRENT | 60A | 31.3A | 20.9A | 15.7A | |||
RATED POWER | 720W | 751.2W | 752.4W | 753.6W | |||
RIPPLE &NOISE(max.)Note.2 | 150mVp-p | 200mVp-p | 250mVp-p | 250mVp-p | |||
VOLTAGE ADJ.RANGE | 12~14.4V | 24~28.8V | 36~43.2V | 48~57.6V | |||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP,RISE TIME Note.4 | 1000ms,50ms/230VAC 1000ms,50ms/115VAC at full load | ||||||
HOLD UPTIME (Typ. | 12ms/230VAC 12ms/115VAC | ||||||
INPUT | VOLTAGE RANGE Note.4 | 90~264VAC 127~370VDC | |||||
FREQUENCYRANGE | 47~63Hz | ||||||
POWER FACTOR(Typ.)Note.4 | PF≥0.95/230VAC PF≥0.98/115VAC atfull load | ||||||
EFFICIENCY(Typ. | 93.5% | 95% | 95% | 95% | |||
AC CURRENT(Typ. | 7.5A/115VAC 3.8A/230VAC | ||||||
INRUSH CURRENT(Typ. | Cold start 20A/115VAC 40A/230VAC | ||||||
LEAKAGE CURRENT | <0.75mA/240VAC | ||||||
PROTECTION | OVERLOAD | 105~125%rated output power | |||||
Protection type:Hiccup mode,recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 14.5~16V | 29~33V | 43.5~49V | 59~66V | |||
Protection type:Shut down O/P voltage,re-poweron to recover | |||||||
OVER TEMPERATURE | Protection type:Shut down O/P voltage,recovers automatically after temperature goes down | ||||||
FUNCTION | DC-OK SIGNAL | Contact rating(max.):30Vdc/1A resistive load | |||||
ENVIRONMENT | WORKING TEMP. | -30~+70ºC(Referto "Derating Curve") | |||||
WORKING HUMIDITY | 20~90%RH non-condensing | ||||||
STORAGE TEMP.,HUMIDITY | -40~+85ºC,10~95%RH non-condensing | ||||||
TEMP.COEFFICIENT | ±0.03%/ºC (0~50ºC) | ||||||
VIBRATION | 10~500Hz,5G 10min./1cycle,60min.each along X,Y,Zaxes | ||||||
SAFETY & EMC (Note.5) |
SAFETY STANDARDS | UL62368-1,TUVBS EN/EN62368-1,EAC TP TC 004 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25ºC/70%RH | ||||||
EMC EMISSION | Parameter | Standard | Test Level /Note | ||||
Conducted | BS EN/EN55032(CISPR32) | Class B | |||||
Radiated | BS EN/EN55032(CISPR32) | Class B | |||||
Harmonic Current | BS EN/EN61000-3-2 | ClassA | |||||
Voltage Flicker | BS EN/EN61000-3-3 | ||||||
EMC IMMUNITY | BS EN/EN55035,BS EN/EN61000-6-2 | ||||||
Parameter | Standard | Test Level /Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3,8KVair;Level 2,4KV contact | |||||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||||
FFT/Burst | BS EN/EN61000-4-4 | Level3 | |||||
Surge | BS EN/EN61000-6-2 | 2KV/Line-Line 4KV/Line-Earth | |||||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95%dip0.5periods,30%dip 25 periods, >95%interruptions 250 periods |
|||||
OTHERS | MTBF | 833.9K hrs min.Telcordia SR-332 (Bellcore);104.9Khrs min.MIL-HDBK-217F(25ºC) | |||||
DIMENSION | 237*100*41mm(L*W*H) | ||||||
PACKING | 1.4kg;10pcs/15kg/0.8CUFT | ||||||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measured at 20MHz ofbandwidth byusing a 12"twisted pair-wire terminated with a 0.1uf &47uf parllel capacitor. 3.Tolerance sincludes set up tolerance,line regulation and load regulation. 4.Derating may be needed under low inputvoltages.Please check the derating curve and Static characteristics for more details. 5.The power supply is considered a component whichwillbe instlled into a final quipment.Allthe EMC tests are been executed by mountng the unit on a360mm*360mm metal plate with 1mm of thickness.The inal equipment must be re-confimed that i sil meets EMC drectves.For guidance on howto perfom these EMC tests,please refer to"EMI testing of component power supplies. " 6.The ambient emperature deratng of 3.5ºC1000m with fanless modes and of5ºC1000m wit fan modes for operating altude higher than 2000m(6500) |