MODEL | WDR-60-5 | WDR-60-12 | WDR-60-24 | WDR-60-48 | |||
OUTPUT | DC VOLTAGE | 5V | 12V | 24V | 48V | ||
RATED CURRENT | 10A | 5A | 2.5A | 1.25A | |||
CURRENT RANGE | 0~10A | 0~5A | 0~2.5A | 0~1.25A | |||
RATED POWER | 50W | 60W | 60W | 60W | |||
RIPPLE&NOISE(max.)Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |||
VOLTAGEADJ.RANGE | 5~6V | 12~15V | 24~29V | 48~57V | |||
VOLTAGE TOLERANCE Note.3 | ±2% | ±1.5% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
LOAD REGULATION | 1.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP,RISE,HOLD UP TIME | 1000ms,70ms,20ms/400Vac 2000ms,70ms,10ms/230Vac at full load | ||||||
INPUT | VOLTAGE RANGE Note.4 | 180~550Vac or 254~780Vdc | |||||
FREQUENCY RANGE | 47~63Hz | ||||||
EFEICIENCY(Typ. | 83.5%1400Vac | 86.5%/400Vac | 89%/400Vac | 90.5%/400Vac | |||
AC CURRENT | 0.4A/400Vac 0.7A/230Vac | ||||||
INRUSH CURRENT(max.) | COLD START 50A/400Vac 30A/230Vac | ||||||
LEAKAGE CURRENT | <2mA/530Vac | ||||||
PROTECTION | OVERLOAD | 105~135%rated output power | |||||
Hiccup mode when output voltage <50%,recovers automatically after fault condition is removed Constant current limiting within 50%~100%rated output voltage,recovers automatically after fault condition is removed |
|||||||
OVER VOLTAGE | 6.2~7.2V | 16~18V | 31~37V | 58~60.5V | |||
Protection type:Shut down o/p voltage,re-power on to recover | |||||||
OVER TEMPERATURE | Protection type:Shut down o/p voltage,re-power on to recover | ||||||
FUNCTION | DC OK SIGNAL | Relay contact rating(max.):30V/1Aresistive | |||||
ENVIRONMENT | WORKING TEMP. | -30~+85ºC(Refer to "Derating Curve") | |||||
WORKING HUMIDITY | 20~90%RH non-condensing | ||||||
STORAGE TEMP. | -40~+85ºC | ||||||
TEMP.COEFFICIENT | ±0.03%ºC (0~60ºC) | ||||||
VIBRATION | Component:10~500Hz,2G 10min./1cycle,60min.each along X,Y,Zaxes;Mounting clip:Compliance to IEC60068-2-6 | ||||||
OPERATINGALTITUDE Note.5 | 2000 meters | ||||||
OVER VOLTAGECATEGORY | ;According to EN61558,EN50178,EN60664-1,EN62477-1,EN60204-1;altitude up to 2000 meters | ||||||
SAFETY& EMC (Note 7) |
SAFETY STANDARDS | UL61010,BS EN/EN61558-2-16,AS/NZS 62368.1,EAC TPTC004 approved;design refer toGLand BS EN/EN60204-1(By request) | |||||
WITHSTAND VOLTAGE | /P-O/P:4.7KVAC I/P-FG:2.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25ºC/70%RH | ||||||
EMC EMISSION | Parameter | Standard | Test Level/Note | ||||
Conducted | BS EN/EN55032(CISPR32) | Class B | |||||
Radiated | BSEN/EN55032(CISPR32) | Class B | |||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | |||||
Voltage Flicker | BS EN/EN61000-3-3 | ||||||
EMC IMMUNITY | BS EN/EN55035,BS EN/EN61000-6-2,BS EN/EN61204-3 | ||||||
Parameter | Standard | Test Level /Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3,8KVair;Level2,4KV contact,criteriaA | |||||
Radiated Susceptibility | BSEN/EN61000-4-3 | Level 3,10V/m,criteriaA | |||||
EFTBursts | BS EN/EN61000-4-4 | Level 3,2KV/5KHz,criteria A | |||||
Surge | BSEN/EN61000-4-5 | Level 4,2KV/Line-Line,4KV/Line-Earth,criteriaA | |||||
Conducted | BS EN/EN61000-4-6 | Level 3,10V,criteria A | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level4,30A/m,criteriaA | |||||
Voltage Dips and interruptions | BS EN/EN61000-4-11 | >95%dip0.5 periods,30%dip 25 periods, >95%interruptions 250 periods |
|||||
OTHERS | MTBF | 1900.1Khrs min.Telcordia SR-332(Bellcore);313.7K hrs min.MIL-HDBK-217F (25ºC) | |||||
DIMENSION | 32*125.2*102mm (W*H*D) | ||||||
PACKING | 0.5Kg;28pcs/15.2Kg/1.24CUFT | ||||||
NOTE | 1.All parameters NOT specially mentioned are measured at 400VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measured at 20MHz of bandwidth byusing a 12"twisted pair-wire terminated with a0.1μF&47μF parall capacitor. 3.Tolerance :includes set up tolerance,line regulation and load regulaton. 4.Deratina mav be needed under low input voltage.Please check the deratina curve for more details 5.The ambient temperature derating of 3.5ºCA000m with fanless models and of 5ºC1000m with fan models for operating aliude higher than 2000m(6500ft). 6.Instalation clearances :40mm on top,20mm on the bottom,5mm on the left and right side are recommended when loaded permanently with full power.In case the adjacent device is a heat source,15mm clearance is recommended. 7.The power suppl is considered a component which wil e installd into a final equipment.The final equipment must be reconfrmed thatitsill meets EMC directives.For guidance on how to perform these EMC tests,please refer to "EMI testing of component power supplies. " |