Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Output Type: | Dual |
| Warranty: | >2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Model | D-50A | D-50B | D-50C | D-50F | ||||
| CH1 | CH2 | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 | |
| DC output voltage, current |
5V 0~6A | 12V 0~2A | 5V 0~6A | 24V 0~1A | 12V 1~2A | -12V 0.3~2A | 12V 1~2A | 24V 0.2~1A |
| Wave and noise | 50mVp-p | 80mVp-p | 50mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 120mVp-p |
| Inlet wire stabilily | ±0.5% | ±1% | ±0.5% | ±1% | ±1% | ±1% | ±1% | ±1% |
| Load stability | ±0.5% | ±4% | ±0.5% | ±1% | ±0.5% | ±5% | ±0.5% | ±8% |
| Efficiency | 73% | 73% | 73% | 73% | ||||
| Adjustable range for DC voltage |
CH1:±10% | CH2:±5% | CH1:±10% | CH2:±5% | CH1:±10% | CH2:±10% | CH1:±10% | CH2:±10% |
| Input voltage range | 90~132VAC/180~264VAC by switch 254~370VDC 47~63Hz | |||||||
| Impact current | Cold start current 18A/115VAC 36A/230VAC | |||||||
| Overload protection | 105% -150% cut off the output, automatic recovery | |||||||
| Over voltage protection | CH1:115% -135% shut down O/P voltage, re-power on to recover | |||||||
| Setup, rise, hold up time | 200ms, 100ms, 30ms/230VAC at full load | |||||||
| Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV OP-FG: 0.5kV 1 minute | |||||||
| Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | |||||||
| Working temperature | -10ºC~+50ºC | |||||||
| Dimension | 159 x 98 x 38mm | |||||||
| Weight | 0.55kg | |||||||
| Packing | 34 x 32 x 24CM/30PCS/16.5kg | |||||||




Q1:Are you a factory or trading company?