SDR Series 960W 24V 40A 48V 20A Mean Well PLC Industrial Control Parallel Switching Power Supply
MODEL | SDR-960-24 | SDR-960-48 | |
0UTPUT | DC VOLTAGE | 24V | 48V |
RATED CURRENT | 40A | 20A | |
CURRENT RANGE | 0~40A | 0~20A | |
RATED POWER | 960W | 960W | |
PEAK CURRENT | 52A | 26A | |
PEAK POWER Note.6 | 1248W (3sec.) | ||
RIPPLE &NOISE(max.)Note.2 | 180mVp-P | 250mVp-p | |
VOLTAGE ADJ.RANGE | 24~28V | 48~55V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | |
SETUP,RISE TIME | 1000ms,100ms/230VAC at full load | ||
HOLDUPTIME(Typ.) | 14ms/230VAC at full load | ||
INPUT | VOLTAGE RANGE Note.7 | 180~264VAC 254~370VDC | |
FREQUENCY RANGE | 47~63Hz | ||
POWER FACTOR(Typ. | PF≥0.95/230VAC at full load | ||
EFFICIENCY(Typ. | 94% | 94% | |
AC CURRENT (Typ.) | 6A/230VAC | ||
INRUSH CURRENT (Typ.) | COLD START 50A/230VAC | ||
LEAKAGE CURRENT | <3.5mA/240VAC | ||
PROTECTION | OVERLOAD | Normally works within 105~130%rated output power for more than 3seconds and then shut down o/p voltage with auto-recovery after30 seconds if the peak load condition is removed |
|
Constant current limiting within 130~150%ated output power for more than 3 seconds and then shut down o/p voltage,re-power on to recover |
|||
OVER VOLTAGE | 29~33V | 56~65V | |
Protection type:Shut down o/p voltage,with auto-recovery or re-power on to recover | |||
OVER TEMPERATURE | Shut down o/p voltage,recovers automatically after temperature goes down | ||
FUNCTION | DC OK REALY CONTACTRATINGS (max.) | 60Vdc/0.3A,30Vdc/1A,30Vac/0.5Aresistive load | |
CURRENT SHARING | Please refer to function manual | ||
ENVIRONMENT | WORKING TEMP. Note.5 | -30~+70ºC(Referto "Derating Curve") | |
WORKING HUMIDITY | 20~95%RH non-condensing | ||
STORAGE TEMP.,HUMIDITY | -40~+85ºC,10~95%RH non-condensing | ||
TEMP.COEFFICIENT | ±0.03%/ºC (0~50ºC) | ||
VIBRATION | Component:10~500Hz,2G 10min./1cycle,60min.each along X,Y,Zaxes;Mounting:Compliance to IEC60068-2-6 | ||
SAFETY& EMC (Note 4) |
SAFETY STANDARDS | UL508,TUV BS EN/EN62368-1,BSMICNS14336-1,AS/NZS62368.1,EAC TPTC 004 approved;(meet BSEN/EN60204-1 | |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC | ||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:>100M Ohms/500VDC/25ºC/70%RH | ||
EMC EMISSION Note.8 | Compliance to BS EN/EN55032(CISPR32),BSEN/EN61204-3 Conduction class B,Radiation class A,BS EN/EN61000-3-2,-3, EAC TP TC020,BSMI CNS13438,KCKSC 9832 |
||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55024,BS EN/EN61000-6-2(BS EN/EN50082-2),BS EN/EN61204-3, heavy industry level,EAC TPTC020,KC KSC 9835 |
||
OTHERS | MTBF | 660.2K hrs min.Telcordia SR-332(Bellcore);70.7K hrs min. MIL-HDBK-217F (25ºC) | |
DIMENSION | 110*125.2*150mm(W*H*D) | ||
PACKING | 2.47Kg;6pcs/15.8Kg/1.55CUFT | ||
NOTE | 1.All parameters NOT spedially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor 3.Tolerance :includes set up tolerance,line regulation and load regulation. 4.The power supply is considered a component which wil be installd into a finalequipment.The final equipment must be re-confmed thatit sil meets EMC directives. 5.Instalation cearances:40mm on top,20mm on the bottom,5mm on the let and ight side are recommended whenoaded pemanenty with ful power In case the adjacent device is a heat source,15mm clearance is recommended. 6.3 seconds peak power max.and the average output power should not exceed the rate power. 7.Derating may be needed under low input voltage.Please check the derating curve for more details. 8.Consult MEAN WELL for deployment of Radiation class B. 9.The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altude higher than 2000m(6500) |
Q1:Why choose us?
A1:Original MEANWELL brand 100% original real MEANWELL brand, and have UL, CUL, CE, CB, RoHS and other certificates. The product surface has different S/N codes, you can check the code with MEANWELL company.
Q2: Do you have any MOQ limit?
A2: No MOQ, for most models we have stock 1pcs also ok. If the model not commonly used, we will quote the price and MOQ.
Q3:What about the lead time?
A3:Delivery time about 3-7 days, mass production time depends on order quantity and model.
Q4:How do you ship the goods and how long does it takes?
A4:We usually ship via DHL, UPS, FedEx or TNT. It will takes about 3-7 days to arrive. Airline and sea shipping also optional.
Q5:Do you offer guarantee for the products?
A5:Off course, 2-7 years warranty.