MODEL | RSP-2000-12 | RSP-2000-24 | RSP-2000-48 | |
OUTPUT | DC VOLTAGE | 12V | 24V | 48V |
RATED CURRENT | 100A | 80A | 42A | |
CURRENT RANGE | 0~100A | 0~80A | 0~42A | |
RATED POWER | 1200W | 1920W | 2016W | |
RIPPLE&NOISE (max.)Note.2 | 150mVp-p | 200mVp-p | 300mVp-p | |
VOLTAGE ADJ.RANGE | 10.5~14V | 21~28V | 42~56V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | |
SETUP,RISE TIME | 1500ms,60ms/230VACat full load | |||
HOLD UP TIME(Typ.) | 16ms/230VACat75%load 10ms/230VAC at full load | |||
INPUT | VOLTAGE RANGE Note.4,5 | 90~264VAC 250~320VDC | ||
FREQUENCY RANGE | 47~63Hz | |||
POWER FACTOR(Typ.) | 0.97/230VAC at full load | |||
EFFICIENCY(Typ.) | 87% | 90.5% | 92% | |
AC CURRENT(Typ.) Note.4 | 13A/115VAC 7A/230VAC | 16A/115VAC 10A/230VAC | 16A/115VAC 10A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 50A | |||
LEAKAGECURRENT | <2mA/240VAC | |||
PROTECTION | OVERLOAD | 105~125%rated output power | ||
Protection type:Constant current limiting,unit will shut down o/p voltage after 5 sec.re-power on to recover | ||||
OVER VOLTAGE | 14.7~17.5V | 29.5~35V | 57.6~67.2V | |
Protection type:Shut down o/p voltage,re-power on to recover | ||||
OVER TEMPERATURE | Shut down o/p voltage,recovers automatically after temperature goes down | |||
FUNCTION | 0UTPUTVOLTAGE PROGRAMMABLE(PV) | Adjustment of output voltageis allowable to 40~115%of nominal output voltage.Please refer to the Function Manual. | ||
CURRENT SHARING | Up to 8000Wor (3+1)units.Please referto the Function Manual. | |||
AUXILIARY POWER | [email protected],[email protected] | |||
REMOTE ON-OFF CONTROL | By electrical signal or dry contact Power ON:open Power OFF:short.Please refer to the Function Manual. | |||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.5V.Please refer to the Function Manual. | |||
DC OK SIGNAL | The isolated TTL signal out.Please refer to the Function Manual. | |||
ENVIRONMENT | WORKING TEMP. | -35~+70ºC(Refer to "Derating Curve") | ||
WORKING HUMIDITY | 20~90%RH non-condensing | |||
STORAGE TEMP.,HUMIDITY | -40~+85ºC,10~95%RHnon-condensing | |||
TEMP.COEFFICIENT | ±0.03%/ºC (0~50ºC) | |||
VIBRATION | 10~500Hz,2G 10min./1cycle,60min.each along X,Y,Zaxes | |||
SAFETY& EMC (Note 6) |
SAFETY STANDARDS | UL62368-1,CSAC22.2 No.62368-1,TUVBS EN/EN62368-1,BSMI CNS14336-1,AS/NZS62368.1, BIS IS13252(Part1):2010/IEC 60950-1:2005(except 48V),EACTP TC004 approved |
||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC125ºC170%RH | |||
EMC EMISSION | Parameter | Standard | Test Level /Note | |
Conducted | BS EN/EN55032(CISPR32) | Class B | ||
Radiated | BS EN/EN55032(CISPR32) | ClassA | ||
Harmonic Current | BS EN/EN61000-3-2 | |||
Voltage Flicker | BS EN/EN61000-3-3 | - | ||
EMC IMMUNITY | BS EN/EN55035,BS EN/EN61000-6-2,BSMI CNS13438 | |||
Parameter | Standard | Test Level/Note | ||
ESD | BS EN/EN61000-4-2 | Level 3,8KV air;Level2,4KV contact | ||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | ||
Surge | BS EN/EN61000-4-5 | Level4,4KV/Line-Earth;Level 3,2KV/Line-Line | ||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95%dip 0.5 periods,30%dip 25 periods, >95%interruptions 250 periods |
||
OTHERS | MTBF | 487.7K hrs min.Telcordia SR-332 (Bellcore);42.9K hrs min.MIL-HDBK-217F (25ºC) | ||
DIMENSION | 295*127*41mm(L*W*H) | |||
PACKING | 1.95Kg;6pcs/12.7Kg/1.15CUFT | |||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measuredat 20MHz of bandwidth by using a 12"twisted pair-wire teminated with a 0.1uf &47uf parael capacitor. 3.Tolerance :includes set up tolerance,line regulation and load regulation. 4.Derating may be needed under low input voltages.Please check the derating curve for more details. 5.Please contact MEANWELL for 320~370VDC application. 6.The power supply is considered a component which wil be instaled into a find equipment Al the EMC tests are been executed by mounting the unit on a 720mm*360mm metalplate with 1mm of hickness.Thefial equipment must be re-confirmed that itstll meets EMC drectives.For guidance on how to perform these EMC tests,please refer to "EMI testing of component power supplies. " 7.The ambient temperature derating of 3.5ºC/1ooom with fanless models and of 5ºCA000m with fan models for operating alftude higher than 2000m |