MODEL | DPU-3200-24 | DPU-3200-48 | ||||||||||||||||||||
OUTPUT | DC VOLTAGE | 24V | 48V | |||||||||||||||||||
RATED CURRENT | 133A | 67A | ||||||||||||||||||||
CURRENT RANGE | 0 ~ 133A | 0 ~ 67A | ||||||||||||||||||||
RATED POWER | 3192W | 3216W | ||||||||||||||||||||
RIPPLE & NOISE (max.) Note.2,3 | 300mVp-p | 480mVp-p | ||||||||||||||||||||
VOLTAGE ADJ. RANGE | 23.5 ~ 30V | 47.5 ~ 58.8V | ||||||||||||||||||||
VOLTAGE TOLERANCE Note.4 | ±1.0% | ±1.0% | ||||||||||||||||||||
LINE REGULATION | ±0.5% | ±0.5% | ||||||||||||||||||||
LOAD REGULATION | ±0.5% | ±0.5% | ||||||||||||||||||||
SETUP, RISE TIME | 1500ms, 60ms/230VAC at full load | |||||||||||||||||||||
HOLD UP TIME (Typ.) | 16ms / 230VAC at 75% load 9ms / 230VAC at full load | |||||||||||||||||||||
INPUT | VOLTAGE RANGE Note.5 | 90 ~ 264VAC 127 ~ 370VDC | ||||||||||||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||||||||||||||
POWER FACTOR (Typ.) | 0.97/230VAC at full load | |||||||||||||||||||||
EFFICIENCY (Typ.) Note.6 | 93.5% | 94.5% | ||||||||||||||||||||
AC CURRENT (Typ.) Note.5 | 17A/230VAC | |||||||||||||||||||||
INRUSH CURRENT (Typ.) | COLD START 55A/230VAC | |||||||||||||||||||||
LEAKAGE CURRENT | <2mA / 230VAC | |||||||||||||||||||||
PROTECTION | OVERLOAD | 105 ~ 115% rated current | ||||||||||||||||||||
Protection type : Constant current limiting, shutdown O/Pvoltage after 5 sec. After O/P voltage falls, re-power on to recover | ||||||||||||||||||||||
OVER VOLTAGE | 31.5 ~ 37.5V | 63 ~ 75V | ||||||||||||||||||||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||||||||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||||||||||||||||||
FUNCTION | OUTPUT VOLTAGE PROGRAMMABLE(PV) | Adjustment of output voltage is allowable to 50 ~ 125% of nominal output voltage Please refer to the Function Manual in following pages |
||||||||||||||||||||
CONSTANT CURRENT LEVEL PROGRAMMABLE(PC) | Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual in following pages | |||||||||||||||||||||
REMOTE ON-OFF CONTROL | By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual in following pages | |||||||||||||||||||||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual in following pages | |||||||||||||||||||||
AUXILIARY POWER | 5V @ 0.3A, tolerance ±10%, ripple 150mVp-p, 12V @ 0.8A, tolerance ±10%, ripple 450mVp-p | |||||||||||||||||||||
ALARM SIGNAL | Isolated TTL signal output forT-Alarm and DC-OK. Please refer to the Function Manual in following pages | |||||||||||||||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70ºC (Refer to "Derating Curve") | ||||||||||||||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||||||||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85ºC , 10 ~ 95% RH non-condensing | |||||||||||||||||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |||||||||||||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes | |||||||||||||||||||||
SAFETY & EMC (Note 10) |
SAFETY STANDARDS | UL62368-1, CSAC22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TPTC 004 approved | ||||||||||||||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||||||||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||||||||||||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | |||||||||||||||||||
Conducted | BS EN/EN55032 (CISPR32) | Class B | ||||||||||||||||||||
Radiated | BS EN/EN55032 (CISPR32) | Class A | ||||||||||||||||||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | ||||||||||||||||||||
Voltage Flicker | BS EN/EN61000-3-3 | ----- | ||||||||||||||||||||
EMC IMMUNITY | BS EN/EN55035, BS EN/EN61000-6-2 | |||||||||||||||||||||
Parameter | Standard | Test Level / Note | ||||||||||||||||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||||||||||||||||||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||||||||||||||||||||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | ||||||||||||||||||||
Surge | BS EN/EN61000-4-5 | 2KV/Line-Line 4KV/Line-Earth | ||||||||||||||||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||||||||||||||||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||||||||||||||||||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods |
||||||||||||||||||||
OTHERS | MTBF | 502.9K hrs min. Telcordia SR-332 (Bellcore) ; 44.9K hrs min. MIL-HDBK-217F (25ºC) | ||||||||||||||||||||
DIMENSION | 325.8*107*41mm (L*W*H) | |||||||||||||||||||||
PACKING | 2.76Kg;4pcs/12Kg/0.81CUFT | |||||||||||||||||||||
NOTE | 1. AII parameters NOT speciaIIy mentioned are measured at 230VAC input, rated Ioad and 25ºC of ambient temperature. 2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor. 3. under variabIe Ioad appIication or paraIIeI operation rippIe of the output voItage may be higher than the SPEC at Iight Ioad condition. It wiII go back to normaIrippIe IeveI once the output Ioad is more than 5%. 4. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation. 5. Derating may be needed under Iow input voItages. PIease check the derating curve for more detaiIs. 6. The efficiency is measured at 75% Ioad. 7. If use PV signaI to adjust Vo, under certain operating conditions, rippIe noise of Vo might sIightIy go over rating defined in this specification. 8. Output wiII shut down after O/P voItage is beIow < 80% of Vset for 5 sec, re-power on to recover. 9. when 2 or more PSus are in paraIIeI connection, Iong cabIe(s) used for paraIIeI connection might generate higher noise to communication signaI. Thus, we suggest using proper fiItering part(s) to avoid interference on communication . 10. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by mounting the unit on a 600mm*900mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directives. For guidance on how to perform these EMC tests, pIease refer to "EMI testing of component power suppIies." 11. The ambient temperature derating of 3.5ºC/1000mwithfanIessmodeIsandof5/1000m with fan modeIs for operating aItitude higher than 2000m(6500ft). |
Q1:Why choose us?
A1:Original MEANWELL brand 100% original real MEANWELL brand, and have UL, CUL, CE, CB, RoHS and other certificates. The product surface has different S/N codes, you can check the code with MEANWELL company.
Q2: Do you have any MOQ limit?
A2: No MOQ, for most models we have stock 1pcs also ok. If the model not commonly used, we will quote the price and MOQ.
Q3:What about the lead time?
A3:Delivery time about 3-7 days, mass production time depends on order quantity and model.
Q4:How do you ship the goods and how long does it takes?
A4:We usually ship via DHL, UPS, FedEx or TNT. It will takes about 3-7 days to arrive. Airline and sea shipping also optional.
Q5:Do you offer guarantee for the products?
A5:Off course, 2-7 years warranty.