Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 5 Years |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | RSP-1600-12 | RSP-1600-24 | RSP-1600-27 | RSP-1600-36 | RSP-1600-48 | |||
OUTPUT | DC VOLTAGE | 12V | 24V | 27V | 36V | 48V | ||
RATED CURRENT | 125A | 67A | 59A | 44.5A | 33.5A | |||
CURRENT RANGE | 0~125A | 0~67A | 0~59A | 0~44.5A | 0~33.5A | |||
RATED POWER | 1500W | 1608W | 1593W | 1602W | 1608W | |||
RIPPLE &NOISE(max.)Note.2 | 150mVp-p | 200mVp-p | 200mVp-p | 250mVp-p | 300mVp-p | |||
VOLTAGE ADJ.RANGE | 11.5~15V | 23.5~30V | 26.5~33.5V | 35.5~45V | 47.5~58.8V | |||
VOLTAGE TOLERANCE Note.4 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP,RISE TIME | 1500ms,60ms/230VACat full load | |||||||
HOLD UPTIME(Typ.) | 16ms/230VACat75%load 10ms /230VAC at full load | |||||||
INPUT | VOLTAGE RANGE Note.5 | 90~264VAC 250~370VDC | ||||||
FREQUENCY RANGE | 47~63Hz | |||||||
POWER FACTOR(Typ.) | 0.97/230VAC at full load | |||||||
EFFICIENCY(Typ.) | 89% | 91.5% | 92% | 92% | 93% | |||
AC CURRENT(Typ.) Note.5 | 14A115VAC 8A230VAC | 15A/115VAC 8.5A/230VAC | ||||||
INRUSH CURRENT(Typ.) | COLD START35A/230VAC | |||||||
LEAKAGECURRENT | <2mA/230VAC | |||||||
PROTECTION | OVERLOAD | 105~115%rated current | ||||||
Protection type:Constant current limiting,shut down O/P voltageafter5 sec.After O/P voltage falls,re-power on to recover | ||||||||
OVER VOLTAGE | 15.75~18.75V | 31.5~37.5V | 35.2~41.9V | 47.2~56.3V | 63~75V | |||
Protection type:Shut down o/p voltage,re-power on to recover | ||||||||
OVER TEMPERATURE | Protection type:Shutdown o/p voltage,recoversautomatically after temperature goes down | |||||||
FUNCTION | OUTPUTVOLTAGE PROGRAMMABLE(PV)Note 6 |
Adjustment of output voltageis allowable to 40~125%of nominal outputvoltage(60~125%for 12V). Please refer to the Function Manual. |
||||||
OUTPUT CURRENT PROGRAMMABLE(PC)Note 6 |
Adjustment of constantcurent level is allowable to 20~100%of rated current. Please referto the Function Manual. |
|||||||
AUXILIARY POWER | [email protected],[email protected] | |||||||
REMOTE ON-OFF CONTROL | By electrical signal or dry contact Power ON:short Power OFF:open.Please refer to theFunction Manual | |||||||
REMOTE SENSE | Compensate voltage drop on the loadwiring up to 0.5V.Please refer to the Function Manual | |||||||
ALARM SIGNAL | Isolated signal output for T-alarm and DC OK | |||||||
ENVIRONMENT | WORKING TEMP. | -30~+70ºC(Refer to "DeratingCurve") | ||||||
WORKING HUMIDITY | 20~90%RH non-condensing | |||||||
STORAGE TEMP.,HUMIDITY | -40~+85ºC,10~95%RH non-condensing | |||||||
TEMP.COEFFICIENT | ±0.03%/ºC (0~50ºC) | |||||||
VIBRATION | 10~500Hz,2G 10min./1cycle,60min.each alongX,Y,Zaxes | |||||||
SAFETY& EMC (Note 8) |
SAFETY STANDARDS | UL62368-1,CAN/CSA C22.2 No.62368-1,TUVBS EN/EN62368-1,BSMICNS14336-1,AS/NZS62368.1,EAC TP TC 004 approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC125ºC170%RH | |||||||
EMC EMISSION | Parameter | Standard | Test Level /Note | |||||
Conducted | BS EN/EN55032(CISPR32) | Class B | ||||||
Radiated | BS EN/EN55032(CISPR32) | Class A | ||||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | ||||||
Voltage Flicker | BS EN/EN61000-3-3 | |||||||
EMC IMMUNITY | BS EN/EN55035,BS EN/EN61000-6-2,BSMICNS13438 | |||||||
Parameter | Standard | Test Level /Note | ||||||
ESD | BS EN/EN61000-4-2 | Level 3,8KVair;Level2,4KV contact | ||||||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||||||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | ||||||
Surge | BS EN/EN61000-4-5 | Level 4,2KV/Line-Line 4KV/Line-Earth | ||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||||||
Voltage Dipsand Interruptions | BS EN/EN61000-4-11 | >95%dip 0.5 periods,30%dip 25 periods, >95%interruptions 250 periods |
||||||
OTHERS | MTBF | 478.8K hrsmin.Telcordia SR-332(Bellcore);42.1Khrs min.MIL-HDBK-217F(25ºC) | ||||||
DIMENSION | 300*85*41mm(L*W*H) | |||||||
PACKING | 2.1Kg;6pcs/13.6Kg/1.25CUFT | |||||||
NOTE |
1.All parameters NOT specially menioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measuredat 20MHz of bandwidth by using a 12"twisted pair-wire teminated wih a 0.1uf &47uf paralel capacitor. 3.Under paraleloperation riple of the output voltage may be higherthan the SPEC at light load condifon.It willgo back to normal ipple level once the output load ismore than 5%. 4.Tolerance :includes set up tolerance,line regulation and load regulation. 5.Derating may be needed under low input voltages.Please check the derating curve for more details. 6.PV/PC functions when users are not operaing on PMBUs/CANBus.SVR tuncions when users are neiher operating on PMBusCANBus nor using PV/PC. 7.Output will shut down after O/P voltage is below<80%of Vset for 5 sec,re-power on to recover. 8.The power supply is considered a component which wil be instaled into a find equipment Al the EMC tests are been executed by mountng the unit on a 720mm*360mm metal plate with 1mm of hikness.The fial equipment must be re-confirmed that itstll meets EMC drectves.For guidanceon how to perfom these EMC tests,please refer to "EMI testing of component power supplies. " 9.The ambient temperature derating of 3.5ºCA000m with fanless modes and of 5C1000m with fan models for operatng alitude higher than 2000m |