Customization: | Available |
---|---|
Usage: | Switching, Game Player, Digital Camera, Display |
Output Type: | AC or DC |
Still deciding? Get samples of US$ 5/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | WH-6-5 | WH-6-6 | WH-6-12 | |
Output | DC output voltage | 5V | 6V | 12V |
Output voltage tolerance | 1% | 1% | 1% | |
Rated output current | 1A | 1A | 0.5A | |
Output current range | 0~1A | 0~1A | 0~0.5A | |
output power | 6W | 6W | 6W | |
Ripple and noise | 50mVp-p | 50mVp-p | 50mVp-p | |
DC voltage adjustable range | -9%~+10% | 10% | 10% | |
Start, rise, hold time | 200ms,50ms,20ms/230VAC | |||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | ||
AC input current | 0.35A/230VAC | |||
efficiency | 78% | 78% | 80% | |
Impulse current | Cold start current 30A / 230VAC | |||
Leakage current | <0.5mA/240VAC | |||
Protection | overload protection | 110% - 135% of rated output power start overload protection | ||
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | ||||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | ||
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | |||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | |||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output and ground:0.5kvac | ||
insulation resistance | Input output room: input and ground, output and ground: 100M ohms/ 500VDC | |||
Other | weight | 0.080kg 76*41*28(L*W*H) | ||
Packing | 100pcs |
Model | WH-12-5 | WH-12-9 | WH-12-12 | |
Output | DC output voltage | 5V | 9V | 12V |
Output voltage tolerance | 1% | 1% | 1% | |
Rated output current | 2A | 1A | 1A | |
Output current range | 0~2A | 0~1A | 0~1A | |
output power | 10W | 9W | 12W | |
Ripple and noise | 50mVp-p | 50mVp-p | 50mVp-p | |
DC voltage adjustable range | -9%~+10% | 10% | 10% | |
Start, rise, hold time | 200ms,50ms,20ms/230VAC | |||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | ||
AC input current | 0.35A/230VAC | |||
efficiency | 78% | 78% | 80% | |
Impulse current | Cold start current 30A / 230VAC | |||
Leakage current | <0.5mA/240VAC | |||
Protection | overload protection | 110% - 135% of rated output power start overload protection | ||
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | ||||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | ||
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | |||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | |||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output and ground:0.5kvac | ||
insulation resistance | Input output room: input and ground, output and ground: 100M ohms/ 500VDC | |||
Other | weight | 0.080kg 76*41*28(L*W*H) | ||
Packing | 100pcs |
Model | WH-18-5 | WH-18-6 | WH-18-12 | |
Output | DC output voltage | 5V | 6V | 12V |
Output voltage tolerance | 1% | 1% | 1% | |
Rated output current | 3A | 2.5A | 1.5A | |
Output current range | 0~3A | 0~2.5A | 0~1.5A | |
output power | 15W | 18W | 16W | |
Ripple and noise | 200mVp-p | 200mVp-p | 200mVp-p | |
DC voltage adjustable range | -9%~+10% | 10% | 10% | |
Start, rise,hold time | 200ms,50ms,20ms/230VAC | |||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | ||
AC input current | 0.35A/230VAC | |||
efficiency | 78% | 78% | 80% | |
Impulse current | Cold start current 30A / 230VAC | |||
Leakage current | <0.5mA/240VAC | |||
Protection | overload protection | 110% - 135% of rated output power start overload protection | ||
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | ||||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | ||
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | |||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | |||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output andground: 0.5kvac | ||
insulation Vresistance | Input output room: input and ground, output and ground: 100M ohms/ 500VDC | |||
Other | weight | 0.116kg 83*43.5*31(L*W*H) | ||
Packing | 100pcs |
Model | WH-24-12 | WH-24-24 | |
Output | DC output voltage | 12V | 24V |
Output voltage tolerance | 1% | 1% | |
Rated output current | 2A | 1A | |
Output current range | 0~ 2A | 0~ 1A | |
output power | 24W | 24W | |
Ripple and noise | 50mVp-p | 50mVp-p | |
DC voltage adjustable range | 10% | 10% | |
Start, rise,hold time | 200ms,50ms,20ms/230VAC | ||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | |
AC input current | 0.35A/230VAC | ||
efficiency | 78% | 78% | |
Impulse current | Cold start current 30A / 230VAC | ||
Leakage current | <0.5mA/240VAC | ||
Protection | overload protection | 110% - 135% of rated output power start overload protection | |
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | |||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | |
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | ||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | ||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output and ground: 0.5kvac | |
insulation resistance | Input output room: input and ground, output and ground: 100M ohms / 500VDC | ||
Other | weight | 0.120kg 83*43*31(L*W*H) | |
Packing | 100pcs |
Model | WH-36-12 | WH-36-15 | |
Output | DC output voltage | 12V | 15V |
Output voltage tolerance | 1% | 1% | |
Rated output current | 3A | 2A | |
Output current range | 0~ 3A | 0~ 2A | |
output power | 36W | 36W | |
Ripple and noise | 100mVp-p | 100mVp-p | |
DC voltage adjustable range | 10% | 10% | |
Start, rise, hold time | 200ms,50ms,20ms/230VAC | ||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | |
AC input current | 0.35A/230VAC | ||
efficiency | 78% | 78% | |
Impulse current | Cold start current 30A / 230VAC | ||
Leakage current | <0.5mA/240VAC | ||
Protection | overload protection | 110% - 135% of rated output power start overload protection | |
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | |||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | |
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | ||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | ||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output and ground: 0.5kvac | |
insulation resistance | Input output room: input and ground, output and ground: 100M ohms / 500VDC | ||
Other | weight | 0.140kg ' 93.5*43.5*33(L*W*H) | |
Packing | 100pcs |
Model | WH-48-12 | WH-48-24 | |
Output | DC output voltage | 12V | 24V |
Output voltage tolerance | 1% | 1% | |
Rated output current | 4A | 2A | |
Output current range | 0~4A | 0~ 2A | |
output power | 48W | 48W | |
Ripple and noise | 80mVp-p | 80mVp-p | |
DC voltage adjustable range | 10% | 10% | |
Start, rise, hold time | 200ms,50ms,20ms/230VAC | ||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | |
AC input current | 0.35A/230VAC | ||
efficiency | 82% | 82% | |
Impulse current | Cold start current 30A / 230VAC | ||
Leakage current | <0.5mA/240VAC | ||
Protection | overload protection | 110% - 135% of rated output power start overload protection | |
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | |||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | |
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | ||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | ||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output and ground: 0.5kvac | |
insulation resistance | Input output room: input and ground, output and ground: 100M ohms / 500VDC | ||
Other | weight | 0.180kg ' 115*50*30 (L*W*H) | |
Packing | 100pcs |
Model | WH-60-12 | WH-60-24 | |
Output | DC output voltage | 12V | 24V |
Output voltage tolerance | 1% | 1% | |
Rated output current | 5A | 2.5A | |
Output current range | 0~ 5A | 0~ 2.5A | |
output power | 60W | 60W | |
Ripple and noise | 50mVp-p | 50mVp-p | |
DC voltage adjustable range | 10% | 10% | |
Start, rise, hold time | 200ms,50ms,20ms/230VAC | ||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | |
AC input current | 0.35A/230VAC | ||
efficiency | 78% | 78% | |
Impulse current | Cold start current 30A / 230VAC | ||
Leakage current | <0.5mA/240VAC | ||
Protection | overload protection | 110% - 135% of rated output power start overload protection | |
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | |||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | |
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | ||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | ||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output and ground: 0.5kvac | |
insulation resistance | Input output room: input and ground, output and ground: 100M ohms / 500VDC | ||
Other | weight | 0.230kg '118*53*34(L*W*H) | |
Packing | 50pcs |
Model | WH-72-12 | WH-72-24 | |
Output | DC output voltage | 12V | 24V |
Output voltage tolerance | 1% | 1% | |
Rated output current | 6A | 3A | |
Output current range | 0~ 6A | 0~ 3A | |
output power | 72W | 72W | |
Ripple and noise | 150mVp-p | 150mVp-p | |
DC voltage adjustable range | 10% | 10% | |
Start, rise, hold time | 200ms,50ms,20ms/230VAC | ||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | |
AC input current | 0.35A/230VAC | ||
efficiency | 78% | 78% | |
Impulse current | Cold start current 30A / 230VAC | ||
Leakage current | <0.5mA/240VAC | ||
Protection | overload protection | 110% - 135% of rated output power start overload protection | |
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | |||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | |
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | ||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | ||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output and ground: 0.5kvac | |
insulation resistance | Input output room: input and ground, output and ground: 100M ohms / 500VDC | ||
Other | weight | 0.230kg '118*53*34(L*W*H) | |
Packing | 50pcs |
Model | WH-84-12 | WH-84-24 | |
Output | DC output voltage | 12V | 24V |
Output voltage tolerance | 1% | 1% | |
Rated output current | 7A | 3.5A | |
Output current range | 0~ 7A | 0~ 3.5A | |
output power | 84W | 84W | |
Ripple and noise | 80mVp-p | 80mVp-p | |
DC voltage adjustable range | 10% | 10% | |
Start, rise, hold time | 200ms,50ms,20ms/230VAC | ||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | |
AC input current | 0.35A/230VAC | ||
efficiency | 82% | 82% | |
Impulse current | Cold start current 30A / 230VAC | ||
Leakage current | <0.5mA/240VAC | ||
Protection | overload protection | 110% - 135% of rated output power start overload protection | |
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | |||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | |
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | ||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | ||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output and ground: 0.5kvac | |
insulation resistance | Input output room: input and ground, output and ground: 100M ohms / 500VDC |
Model | WH-96-12 | WH-96-24 | |
Output | DC output voltage | 12V | 24V |
Output voltage tolerance | 1% | 1% | |
Rated output current | 8A | 4A | |
Output current range | 0~ 7A | 0~ 4A | |
output power | 96W | 96W | |
Ripple and noise | 80mVp-p | 80mVp-p | |
DC voltage adjustable range | 10% | 10% | |
Start, rise, hold time | 200ms,50ms,20ms/230VAC | ||
Input | Input voltage range | 170~264VAC 47~63Hz,235~373VDC | |
AC input current | 0.35A/230VAC | ||
efficiency | 82% | 82% | |
Impulse current | Cold start current 30A / 230VAC | ||
Leakage current | <0.5mA/240VAC | ||
Protection | overload protection | 110% - 135% of rated output power start overload protection | |
Protection mode: fold type current limit, automatic recovery after removal of abnormal load conditions | |||
Environmental Science |
Working temperature and humidity |
-10 ºC ~ + 60 ºC; 20% ~ 90% RH (please refer to load derate curve) | |
Storage temperature and humidity |
-20 ºC ~ + 85 ºC; 10% ~ 95% RH non condensing | ||
Seismic resistance | 10~ 500Hz, 2G 10min. / 1 cycle, duration 60min, each axis | ||
Security | Pressure resistance | Input output room: 1.5kVac input and ground: 1.5kVac output and ground: 0.5kvac | |
insulation resistance | Input output room: input and ground, output and ground: 100M ohms / 500VDC |
Q1:Are you a factory or trading company?
A1:We are factory.
Q2:Why choose us
A2:We have been engaged in the switching power supply industry for 17 years,We have enough experience to meet your needs.
Q3:How can I get the samples?
A3:You can pay for the sample this time, and we will refund the sample fee for the next batch order.
Q4:How to order?
A4:Please contact us online to send you a proforma invoice or send us your purchase order by email.
Q5:How many years warranty of your switching power supply?
A5: Three years.