MODEL | UHP-500R-5 | UHP-500R-12 | UHP-500R-15 | UHP-500R-24 | UHP-500R-36 | UHP-500R-48 | UHP-500R-55 | ||
OUTPUT | DC VOLTAGE | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V | 55V |
RATED CURRENT | 80A | 80A | 41.7A | 33.4A | 20.9A | 13.9A | 10.45A | 8.9A | |
RATED POWER | 336W | 400W | 500.4W | 501W | 501.6W | 500.4W | 501.6W | 500W | |
RIPPLE &NOISE(max.)Note.2 | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 240mVp-p | 360mVp-p | 360mVp-p | 500mVp-p | |
VOLTAGEADJ.RANGE Note.7 | 3.6~4.4V | 4.5~5.5V | 11.4~12.6V | 14.3~15.8V | 22.8~25.2V | 34.2~37.8V | 45.6~50.4V | 45~58V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP,RISE TIME | 1000ms,50ms/230VAC;1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time | ||||||||
HOLD UP TIME (Typ. | 12ms/230VAC 12ms/115VAC | ||||||||
INPUT | VOLTAGE RANGE Note.4 | 90~264VAC 127~370VDC | |||||||
FREQUENCY RANGE | 47~63Hz | ||||||||
POWER FACTOR(Typ.) | PF≥0.95/230VAC PF≥0.98/115VAC at full load | ||||||||
EEFICIENCY(Typ. | 89% | 90% | 94% | 94% | 94.5% | 95% | 95% | 95% | |
AC CURRENT(Typ.) | 4.85A/115VAC 2.6A/230VAC | ||||||||
INRUSH CURRENT (Typ.)Note9 | Cold start 30A/115VAC 60A/230VAC | ||||||||
LEAKAGE CURRENT | <0.75mA/240VAC | ||||||||
PROTECTION | OVERLOAD | 110~140%rated output power | |||||||
Protection type:Hiccup mode,recovers automatically afterfault condition is removed | |||||||||
OVERVOLTAGE | 4.62~5.46V | 5.75~6.75V | 13.2~15.6V | 16.5~19.5V | 26.4~31.2V | 39.6~46.8V | 52.8~62.4V | 60~69V | |
Protection type :Shutdown O/P voltage,re-power on to recover | |||||||||
OVER TEMPERATURE | Protection type:Shut down O/P voltage,recovers automatically after temperature goes down | ||||||||
FUNCTION | DC OKSIGNAL(Optional) | Contact rating(max.):30Vdc/1Aresistive load | |||||||
REDUNDANT(Optional) | For parallel connection protection:For parallel applications,when one PSU can not work,the another one will be automatically enabled.This can prevent the system crash,and provide the reliability of system |
||||||||
ENVIRONMENT | WORKING TEMP. | -30~+70ºC(Refer to "Derating Curve") | |||||||
WORKING HUMIDITY | 20~95%RH non-condensing | ||||||||
STORAGE TEMP.,HUMIDITY | -40~+85ºC,10~95%RH non-condensing | ||||||||
TEMP.COEFFICIENT | ±0.03%/ºC (0~50ºC) | ||||||||
VIBRATION | 10~500Hz,5G 10min./1cycle,60min.each along X,Y,Zaxes | ||||||||
SAFETY& EMC (Note.6) |
SAFETY STANDARDS | UL62368-1,TUV BS EN/EN62368-1,BS EN/EN60335-1(Exceptfor 55V),BS EN/EN61558-1,BS EN/EN61558-2-16 GB 4943.1,BSMI CNS14336-1,EAC TP TC 004 approved;Design referto AS/NZS 61558.12.16,AS/NZS 62368.1 |
|||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,0/P-FG:100M Ohms/500VDC/25ºC/70%RH | ||||||||
EMC EMISSION | Compliance to BS EN/EN55032,GB17625.1,GB/T 9254.1,Class B,BS EN/EN61000-3-2,-3,BSMI CNS13438, EAC TP TC 020 |
||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2(BS EN/EN50082-2),BS EN/EN55035 heavy industry level ,EAC TPTC 020 |
||||||||
OTHERS | MTBF | 1264.1K hrs min.Telcordia SR-332(Bellcore);167.6K hrs min.MIL-HDBK-217F (25ºC) | |||||||
DIMENSION | 232*81*31mm (L*W*H) | ||||||||
PACKING | 0.905kg;16pcs/15.48kg/0.82CUFT | ||||||||
NOTE |
1.Al parameters NOT specially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measured at 20MHz of bandwidth byusing a 12"twisted pair-wire terminated with a 0.1uf &47uf paralel capacitor. 3.Tolerance includes set uptolerance,line regulation and load regulation. 4.Derating may be needed under lowinput voltages.Please checkthe derating curve for more details. 5.The ambient temperature derating of 3.5ºC/1000m is needed for operating alitude greater than 2000m(6500ft) 6.The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed thatit sill meets EMC directives.For guidance on how to perform these EMC tests,please refer to"EMIl esting of component power suplies." 7.Please refer to derating curve. 8.R type efficiency slightly less than the Blank type,according to the actual measurement. 9.Inrush current parameter has10%tolerance. 10.RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417. |