Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 5 Years |
Still deciding? Get samples of US$ 345/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment methods: | |
---|---|
Support payment in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | RSP-2400-12 | RSP-2400-24 | RSP-2400-48 | |
OUTPUT | DC VOLTAGE | 12V | 24V | 48V |
RATED CURRENT | 166.7A | 100A | 50A | |
CURRENT RANGE | 0~166.7A | 0~100A | 0~50A | |
RATED POWER | 2000.4W | 2400W | 2400W | |
RIPPLE&NOISE(max.)Note.2 | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGEADJ.RANGE | 10.8~13.2V | 22~28V | 43~56V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | |
INE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SETUP,RISE TIME | 1000ms,80ms at full load | |||
HOLD UPTIME(Typ.) | 12ms at full load | |||
INPUT | VOLTAGE RANGE | 180~264VAC 254~370VDC | ||
FREQUENCYRANGE | 47~63Hz | |||
POWERFACTOR(Typ.) | 0.95/230VAC at full load | |||
EFFICIENCY(Typ.) | 88% | 90.5% | 91.5% | |
AC CURRENT (Typ.) | 15.5A/180VAC 12A/230VAC | |||
INRUSH CURRENT (Typ.) | 60A/230VAC | |||
LEAKAGE CURRENT | <2.0mA/240VAC | |||
PROTECTION | OVERLOAD (OLP) | 100~112%rated output power | ||
User adjustable continuousconstant current limiting or constant current limiting with delay shutdown fter 5 seconds,re-power on to recover | ||||
OVER VOLTAGE | 13.8~16.8V | 28.8~33.6V | 57.6~67.2V | |
Protection type:Shut down o/p voltage,re-power on to recover | ||||
OVER TEMPERATURE | Shut down o/p voltage,recovers automatically aftertemperature goes down | |||
FUNCTION | OUTPUT VOLTAGE PROGRAMMABLE(PV) |
2.4~13.2V | 4.8~28V | 9.6~56V |
Please refer to the Function Manual. | ||||
CURRENT SHARING | Up to 7200Wor(2+1)units.Please refer to the Function Manual. | |||
AUXILIARY POWER | [email protected](Only for Remote ON-OFF control) | |||
REMOTE ON-OFF CONTROL | Please refer to the Function Manual | |||
REMOTE SENSE | Compensate voltage drop on the loadwiring up to 0.25V.Please refer to the Function Manual. | |||
ALARM SIGNALOUTPUT | Power OK signal.Please refer to the Function Manual | |||
ENVIRONMENT | WORKING TEMP. | -20~+70ºC(Refer to "Derating Curve") | ||
WORKING HUMIDITY | 20~90%RH non-condensing | |||
STORAGE TEMP.,HUMIDITY | -40~+85ºC,10~95%RH non-condensing | |||
TEMP.COEFFICIENT | ±0.05%/ºC(0~50ºC) | |||
VIBRATION | 10~500Hz,2G 10min./1cycle,60min.eachalongX,Y,Z axes | |||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL62368-1,CSAC22.2 No.62368-1,TUVBS EN/EN62368-1,BSMI CNS14336-1,AS/NZS62368.1,IS13252(Part1)IEC60950-1, EAC TP TC 004 approved |
||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC125ºC/70%RH | |||
EMC EMISSION | Parameter | Standard | Test Level/Note | |
Conducted | BS EN/EN55032(CISPR32) | Class B | ||
Radiated | BS EN/EN55032(CISPR32) | Class A | ||
Harmonic Current | BS EN/EN61000-3-2 | |||
Voltage Flicker | BS EN/EN61000-3-3 | - | ||
EMC IMMUNITY | BS EN/EN55035,BS EN/EN61000-6-2,BSMI CNS13438 | |||
Parameter | Standard | Test Level /Note | ||
ESD | BS EN/EN61000-4-2 | Level 3,8KVair;Level 2,4KV contact | ||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | ||
Surge | BS EN/EN61000-4-5 | Level 3,2KV/Line-Earth;Level2,1KV/Line-Line | ||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95%dip 0.5 periods,30%dip 25 periods, >95%interruptions250 periods |
||
OTHERS | MTBF | 692.3Khrs min.Telcordia SR-332 (Bellcore);83.9K hrs min.MIL-HDBK-217F(25ºC) | ||
DIMENSION | 278*177.8*63.5mm(L*W*H) | |||
PACKING | 3.3Kg;4pcs/14.2Kg/2.04CUFT | |||
NOTE |
1.Al parameters NOT specially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire teminated with a 0.1uf &47uf parllel capacitor. 3.Tolerance :includes set up tolerance,line regulation and load regulation. 4.The power supply is considered a component which wilbe instaled into a fina equipment Al the EMC tests are been executed by mountng the unit on a 720mm*360mm metal plate with 1mm of hickness.Thefial equipment must be re-confirmed that t stll meets EMC drectves.For guidance on how to perform these EMC tests,please refer to "EMl testing of component power supplies. " (as available on Upload/PDF/EMI_statement_en.pdf) 5.The ambient temperature deratng of 3.5ºC1000m withfanless models and of 5C/1000m with fanmodels for operatng alitude higher than2000m |