Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | >2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1.Full range AC 85-264V Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty

| Model | LRS-400-12 | LRS-400-15 | LRS-400-24 | LRS-400-36 | LRS-400-48 |
| DC Voltage | 12V | 15V | 24V | 36V | 48V |
| Rated Current | 33A | 26.6A | 16.5A | 11A | 8.3A |
| Current Range | 0~33A | 0~26.6A | 0~16.5A | 0~11A | 0~8.3A |
| Rated Power | 396W | 399W | 396W | 396W | 398.4W |
| Ripple and Noise | 150mvp-p | 150mvp-p | 150mvp-p | 200mvp-p | 200mvp-p |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Setup, Rise time | 1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load | ||||
| Hold up time | 16ms/230VAC 12ms/115VAC at full load | ||||
| Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC) | ||||
| Frequency Range | 47~63HZ | ||||
| Efficiency | 85% | 86% | 88% | 88.5% | 89% |
| AC Current | 6.8A/115VAC 3.4A/230VAC | ||||
| Inrush Current | 60A/115VAC 60A/230VAC | ||||
| Leakage Current | <2mA / 240VAC | ||||
| Over Load | 110 ~ 140% rated output power | ||||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
| Working Temp | -20 ~ +70ºC (Refer to "Derating Curve") | ||||
| Working Humidity | 20 ~ 90% RH non-condensing | ||||
| Storage temp,humidity | -40 ~ +85ºC, 10 ~ 95% RH | ||||
| Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | ||||
| Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| lsolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH | ||||
| Demension | 215*115*30mm (L*W*H) | ||||
| Weight/Packing | 0.76Kg | ||||