Features:
1. AC input range selectable by switch
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
| Model | EDR-150-24 | EDR-150-48 |
| DC output voltage | 24V 0~6.5A | 48V 0~3A |
| Wave and noise | 150mVp-p | 200mVp-p |
| Inlet wire stabilily | ±0.5% | ±0.5% |
| Load stability | ±1% | ±0.5% |
| Efficiency | 87% | 88% |
| Adjustable range for DC voltage | ±10% | ±10% |
| Input voltage range | 85~264VAC 120~370VDC 47~63Hz | |
| Impact current | Cold start current 20A/115VAC 40A/230VAC | |
| Overload protection | 105%~150% cut off the output, automatic recovery | |
| Over voltage protection | 120%~140% shut down O/P voltage, re-power on to recover | |
| Setup, rise, hold up time | 1200ms, 60ms, 60ms/230VAC at full load | |
| Withstand voltage | I/P-O/P: 1.5kV I/P-FG:1.5kV O/P-FG: 0.5kV 1minute | |
| Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | |
| Working temperature | -10ºC~+50ºC | |
| Dimension | 40×125.2×113.5mm | |
| Weight | 0.6kg | |
| Packing | 45.5×35×26CM | |